Literature DB >> 21333583

Spinal landmark depth in relation to body mass index.

Gregory N Kawchuk1, Narasimha Prasad, Eric Parent, Sheena Chapman, Marianne Custodio, Maria Manzon, Amanda Wiebe, Suki Dhillon.   

Abstract

Identifying spinal landmarks by palpation is a prerequisite to many manual therapy procedures. Understanding if landmark depth changes with a subject's body mass index (BMI) may help clinicians attribute importance to their palpation findings. In this study, 105 consecutive subjects were referred for lumbar magnetic resonance imaging (MRI) in a hospital setting. Four blinded examiners measured T1-weighted MRI images to quantify the depth of spinous and transverse processes in the lumbar spine. For each process, a linear mixed-effects model was carried out by gender with depth as the outcome and BMI as a covariate. The average BMI for males (n = 57) was 27.52 kg/m(2) and 27.02 kg/m(2) for females. The mean landmark depth was 22.77 mm, 23.00 mm, 27.40 mm, 33.40 mm, 36.65 mm for spinous processes L1-L5 respectively and 69.35 mm and 69.41 mm for the left and right L4 transverse processes. The inter-evaluator, intra-class correlation coefficient averaged 0.98 for all depth measurements. The linear relationship between depth and BMI was statistically significant for all landmarks in females and only for spinous processes in males. In conclusion, the strength of the correlations observed suggests that although landmark depth increases with subject BMI, other factors may influence this correlation.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 21333583     DOI: 10.1016/j.math.2011.01.007

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  6 in total

1.  Validity of sagittal thoracolumbar curvature measurement using a non-radiographic surface topography method.

Authors:  Erin Hannink; Helen Dawes; Thomas M L Shannon; Karen L Barker
Journal:  Spine Deform       Date:  2022-07-09

2.  The effect of application site of spinal manipulative therapy (SMT) on spinal stiffness.

Authors:  Tiffany L Edgecombe; Greg N Kawchuk; Cynthia R Long; Joel G Pickar
Journal:  Spine J       Date:  2013-10-17       Impact factor: 4.166

3.  Accuracy of Motion Palpation Flexion-Extension Test in Identifying the Seventh Cervical Spinal Process.

Authors:  Luciana C Póvoa; Ana P A Ferreira; José F C Zanier; Julio G Silva
Journal:  J Chiropr Med       Date:  2018-03-01

4.  Abdominal circumference but not the degree of lumbar flexion affects the accuracy of lumbar interspace identification by Tuffier's line palpation method: an observational study.

Authors:  Nan Lin; Yan Li; John F Bebawy; Jia Dong; Lin Hua
Journal:  BMC Anesthesiol       Date:  2015-01-21       Impact factor: 2.217

5.  Structural health monitoring (vibration) as a tool for identifying structural alterations of the lumbar spine: a twin control study.

Authors:  Gregory N Kawchuk; Jan Hartvigsen; Tiffany Edgecombe; Narasimha Prasad; Jaap H van Dieen
Journal:  Sci Rep       Date:  2016-03-11       Impact factor: 4.379

6.  Spinal Palpation Error and Its Impact on Skin Marker-Based Spinal Alignment Measurement in Adult Spinal Deformity.

Authors:  Pieter Severijns; Thomas Overbergh; Stefan Schmid; Lieven Moke; Lennart Scheys
Journal:  Front Bioeng Biotechnol       Date:  2021-06-23
  6 in total