Literature DB >> 21331547

Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique.

S Lenschow1, M Herbort, A Strässer, M Strobel, M Raschke, W Petersen, T Zantop.   

Abstract

INTRODUCTION: In ACL reconstruction using a soft tissue graft, aperture fixation with interference screws (IFS) can lacerate and rotate the graft and cause primary tunnel widening. To overcome these downsides, a new wedge-shaped implant (MegaShim, Karl Storz, Germany) was developed. We hypothesized that aperture fixation of hamstring ACL reconstruction using the MegaShim technique shows comparable structural properties when compared to interference screw fixation.
METHODS: In a porcine knee model, ACL reconstructions with a tunnel diameter of 6, 7, 8 and 9 mm were performed and human hamstring grafts were fixed using the MegaShim technique (group I). In group 2, grafts were fixed in a hybrid fixation using a MegaShim and cortical flip button (FlippTack, Karl Storz, Germany). Interference screw graft fixation served as a control group (group III). Maximum load, yield load and stiffness were recorded using material testing machine. Grafts were cyclically preconditioned between 0 and 20 N for 10 cycles before the graft-bone complex was loaded to failure. Statistical evaluation was performed using SPSS Version 11.0.
RESULTS: Mean maximum load to failure for the hybrid fixation was significantly higher than after interference screw or MegaShim fixation. The difference between MegaShim and interference screw fixation showed no significant difference for 6 and 7 mm sizes. An 8 and 9 mm MegaShim fixation resulted in significantly lower ultimate failure load compared to interference screw fixation. Stiffness of grafts fixed using 6 mm MegaShim was significantly lower than grafts fixed with hybrid or interference screw fixation, whereas no significant differences were found in the 7, 8, and 9 mm fixations.
CONCLUSION: Aperture fixation using the MegaShim technique provides comparable structural properties compared to interference screw fixation. Hybrid fixation using MegaShim and cortical flip button results in significantly higher ultimate failure loads than both aperture fixation approaches. Smaller grafts (6 mm) showed significantly lower ultimate failure load and stiffness than interference screw fixation. The "MegaShim technique" is an alternative to interference screw fixation concerning initial fixation strength.

Entities:  

Mesh:

Year:  2011        PMID: 21331547     DOI: 10.1007/s00402-011-1276-7

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  Biomechanical evaluation of different surgical techniques for treating patellar tendon ruptures.

Authors:  Benedikt Schliemann; Niklas Grüneweller; Daiwei Yao; Clemens Kösters; Simon Lenschow; Steffen B Roßlenbroich; Michael J Raschke; Andre Weimann
Journal:  Int Orthop       Date:  2015-10-03       Impact factor: 3.075

2.  A new anterior cruciate ligament reconstruction fixation technique (quadrupled semitendinosus anterior cruciate ligament reconstruction with polyetheretherketone cage fixation).

Authors:  Philippe Calas; Nicolas Dorval; Anthony Bloch; Jean-Noël Argenson; Sébastien Parratte
Journal:  Arthrosc Tech       Date:  2012-03-31

3.  [Knee laxity in anterior cruciate ligament reconstruction : The influence of graft rotation using interference screw fixation].

Authors:  C Offerhaus; M Balke; M Braas; D Pennig; S Gick; J Höher
Journal:  Orthopade       Date:  2015-03       Impact factor: 1.087

4.  Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation.

Authors:  Janosch Häberli; Maximilian Heilgemeir; Sebastian Valet; Ameet Aiyangar; Tom Overes; Philipp Henle; Stefan Eggli
Journal:  Arch Orthop Trauma Surg       Date:  2021-08-30       Impact factor: 2.928

5.  [Knee laxity in anterior cruciate ligament reconstruction. The influence of graft rotation using interference screw fixation].

Authors:  C Offerhaus; M Balke; M Braas; D Pennig; S Gick; J Höher
Journal:  Unfallchirurg       Date:  2014-09       Impact factor: 1.000

6.  Biomechanical Analysis of Single Interference Screw vs Interference Screw With Cortical Button for Flexor Hallucis Longus Transfer.

Authors:  Kaitlin C Neary; Sarah J McClish; Anthony N Khoury; Nicholas Denove; John Konicek; Coen A Wijdicks
Journal:  Foot Ankle Orthop       Date:  2021-10-18
  6 in total