| Literature DB >> 21331283 |
Julie F Hart1, Tony J Ward, Terry M Spear, Richard J Rossi, Nicholas N Holland, Brodie G Loushin.
Abstract
Wood burning for residential heating is prevalent in the Rocky Mountain regions of the United States. Studies have shown that wood stoves can be a significant source of PM(2.5) within homes. In this study, the effectiveness of an electrostatic filter portable air purifier was evaluated (1) in a home where a wood stove was the sole heat source and (2) in a home where a wood stove was used as a supplemental heat source. Particle count concentrations in six particle sizes and particle mass concentrations in two particle sizes were measured for ten 12-hour purifier on and ten purifier off trials in each home. Particle count concentrations were reduced by 61-85 percent. Similar reductions were observed in particle mass concentrations. These findings, although limited to one season, suggest that a portable air purifier may effectively reduce indoor particulate matter concentrations associated with wood combustion during home heating.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21331283 PMCID: PMC3038427 DOI: 10.1155/2011/324809
Source DB: PubMed Journal: J Environ Public Health ISSN: 1687-9805
Figure 1Configuration of the wood burning stove, Filtrete air purifier, DustTrak aerosol monitor, and Lighthouse particle counter in each home. An additional DustTrak was placed in a secondary location (bedroom) 5.84 meters from the wood stove in Home B.
Figure 2Geometric mean particle count concentrations (particle/m3) observed with the portable air purifier off and on at the one µm cutpoint for each 12-hour trial conducted in home A. Concentrations recorded with the air purifier on were consistently lower than concentrations recorded with the air purifier off. Similar observations were made in terms of particle concentration reductions with the air cleaner on at the other cutpoints.
Home A mean concentrations (particle/m3) measured with the Lighthouse, lower and upper confidence intervals, and percent changes (%).
| Air purifier off | Air purifier on | |||||||
|---|---|---|---|---|---|---|---|---|
| Particle cutpoint ( | Mean concentration (p/m3) | LCI (p/m3) | UCI (p/m3) | Mean concentration (p/m3) | LCI (p/m3) | UCI (p/m3) | Percent change |
|
| 0.3 | 21,921,972 | 15,294,441 | 31,421,408 | 7,579,820 | 5,288,261 | 10,864,379 | −65% | .000 |
| 0.5 | 2,006,696 | 1,317,175 | 3,054,114 | 684,881 | 477,825 | 2,006,696 | −66% | .001 |
| 1 | 257,043 | 169,058 | 390,819 | 96,858 | 63,768 | 147,267 | −63% | .003 |
| 2.5 | ||||||||
| Day | 67,643 | 43,783 | 104,402 | 26,716 | 17,309 | 41,274 | −61% | .002 |
| Night | 30,577 | 19,791 | 47,193 | 12,076 | 7,824 | 18,657 | −61% | .002 |
| 5 | ||||||||
| Day | 14,827 | 10,451 | 21,034 | 5,530 | 3,898 | 7,846 | −63% | .000 |
| Night | 4,565 | 3,218 | 6,476 | 1,703 | 1,203 | 2,416 | −63% | .000 |
| 10 | ||||||||
| Day | 2,502 | 1,895 | 3,616 | 973 | 673 | 1,405 | −61% | .000 |
| Night | 652 | 452 | 942 | 253 | 176 | 366 | −61% | .000 |
Home B mean concentrations (particle/m3) measured with the Lighthouse, lower and upper confidence intervals, and percent changes (%).
| Air purifier off | Air purifier on | |||||||
|---|---|---|---|---|---|---|---|---|
| Particle cutpoint ( | Mean concentration (p/m3) | LCI (p/m3) | UCI (p/m3) | Mean concentration (p/m3) | LCI (p/m3) | UCI (p/m3) | Percent change |
|
| 0.3 | 26,010,218 | 16,452,697 | 41,119,787 | 4,542,554 | 2,870,509 | 7,181,365 | −82% | .001 |
| 0.5 | 2,533,976 | 1,938,451 | 3,312,786 | 441,088 | 337,425 | 576,655 | −83% | .000 |
| 1 | 569,264 | 423,285 | 765,588 | 85,974 | 63,927 | 115,636 | −85% | .000 |
| 2.5 | 206,282 | 126,121 | 337,729 | 32,663 | 19,950 | 53,477 | −84% | .000 |
| 5 | 31,351 | 16,933 | 58,047 | 6,039 | 3,262 | 11,181 | −81% | .002 |
| 10 | ||||||||
| Day | 7,347 | 4,209 | 12,823 | 1,621 | 857 | 3,072 | −78% | .002 |
| Night | 1,239 | 654 | 2,347 | 273 | 157 | 478 | −78% | .002 |
Home A and B particle mass concentrations (μg/m3) measured with the DustTrak, lower and upper confidence intervals, and percent changes (%).
| Air purifier off | Air purifier on | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Home | Particle cutpoint ( | Mean concentration ( | LCI ( | UCI ( | Mean concentration ( | LCI ( | UCI ( | Percent change |
|
| A | 1.0 | 8.85 | 3.94 | 13.8 | 3.72 | 1.15 | 6.28 | −58% | .040 |
| 2.5 | 13.98 | 5.93 | 22.03 | 3.30 | 1.09 | 5.51 | 76% | .025 | |
| B | 1.0 | 7.08 | 0.83 | 13.32 | 3.21 | 0 | 7.60 | −55% | .238 |
| 2.5 | 13.60 | 8.10 | 19.09 | 3.26 | 2.23 | 4.29 | −76% | .007 | |
| B | 1.0 | 6.86 | 2.95 | 10.77 | 1.83 | 0.99 | 2.61 | −74% | .025 |
| Secondary* | 2.5 | 8.88 | 5.27 | 12.49 | 2.22 | 1.63 | 2.82 | −75% | .007 |
*Secondary location (bedroom) in Home B 5.84 meters from wood stove.