Literature DB >> 21325933

Biomechanical comparison of three different types of C7 fixation techniques.

Jae Taek Hong1, Takigawa Tomoyuki, Ranjith Udayakumar, Alejandro A Espinoza Orías, Nozomu Inoue, Howard S An.   

Abstract

Mesh:

Year:  2011        PMID: 21325933     DOI: 10.1097/BRS.0b013e3181d345e0

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


× No keyword cloud information.
  12 in total

1.  The C7 pedicle as a superior fixation point in spinal stabilization for spinal metastatic disease.

Authors:  Harjot Thind; Andrew J Fabiano
Journal:  J Spine Surg       Date:  2018-03

2.  Which salvage fixation technique is best for the failed initial screw fixation at the cervicothoracic junction? A biomechanical comparison study.

Authors:  Jae Taek Hong; Takigawa Tomoyuki; Ashish Jain; Alejandro A Espinoza Orías; Nozomu Inoue; Howard S An
Journal:  Eur Spine J       Date:  2017-07-27       Impact factor: 3.134

3.  Comparison of revision strategies for failed C2-posterior cervical pedicle screws: a biomechanical study.

Authors:  Michael Mayer; Juliane Zenner; Robert Bogner; Wolfgang Hitzl; Markus Figl; Arvind von Keudell; Daniel Stephan; Rainer Penzkofer; Peter Augat; Gundobert Korn; Herbert Resch; Heiko Koller
Journal:  Eur Spine J       Date:  2012-08-28       Impact factor: 3.134

4.  C7 intra-laminar screws for complex cervicothoracic spine surgery-a case series.

Authors:  Peter John Wilson; Michael Derrick Selby
Journal:  J Spine Surg       Date:  2017-12

5.  A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study.

Authors:  Muhammad Qasim; Jae Taek Hong; Raghu N Natarajan; Howard S An
Journal:  J Korean Neurosurg Soc       Date:  2013-06-30

6.  A biomechanical comparison of three different posterior fixation constructs used for c6-c7 cervical spine immobilization: a finite element study.

Authors:  Jae Taek Hong; Muhammad Qasim; Alejandro A Espinoza Orías; Raghu N Natarajan; Howard S An
Journal:  Neurol Med Chir (Tokyo)       Date:  2014-01-10       Impact factor: 1.742

7.  Is polymethyl methacrylate a viable option for salvaging lateral mass screw failure in the subaxial cervical spine?

Authors:  Michael A Gallizzi; Craig A Kuhns; Tyler J Jenkins; Ferris M Pfeiffer
Journal:  Global Spine J       Date:  2014-10-10

8.  C7 intralaminar screw placement, an alternative to lateral mass or pedicle fixation for treatment of cervical spondylytic myelopathy, kyphotic deformity, and trauma: A case report and technical note.

Authors:  Michael T Koltz; Christopher M Maulucci; Charles A Sansur; D Kojo Hamilton
Journal:  Surg Neurol Int       Date:  2014-01-17

9.  Feasibility of bilateral crossing c7 intralaminar screws: a cadaveric study.

Authors:  Tae-Hyun Baek; Ilsup Kim; Jae-Taek Hong; Daniel H Kim; Dongsuk Shin; Sang-Won Lee
Journal:  J Korean Neurosurg Soc       Date:  2014-07-31

Review 10.  Posterior Fixation Techniques in the Subaxial Cervical Spine.

Authors:  Ahmer Ghori; Hai V Le; Heeren Makanji; Thomas Cha
Journal:  Cureus       Date:  2015-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.