Literature DB >> 2132546

A micro-perfusion chamber for single-cell fluorescence measurements.

C Ince1, R E Beekman, G Verschragen.   

Abstract

A versatile closed micro-perfusion chamber designed for single-cell fluorescence measurements under maximum microscopic magnification is described. Glass coverslips with adherent cells can be attached to the top or bottom of the chamber, depending on whether an inverted or an upright microscope is used. Eight conical holes drilled in the side of the chamber serve for the insertion of plugs with attachments for perfusion, rapid injection of small amounts of reagents, temperature measurements or for heating the interior of the chamber. Materials used in the construction of the chamber are non-toxic and resistant to standard sterilization procedures. Perfusion and temperature properties of the chamber are described. Single cell fluorescence measurements are presented in human monocyte-derived macrophages in which NAD(P)H and intracellular calcium are measured.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2132546     DOI: 10.1016/0022-1759(90)90214-g

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  5 in total

1.  A new perfusion cell chamber system for determination of heat shock effects by means of video-enhanced microscopy.

Authors:  A Hofer; F Nagel; F Wonka; H E Krinke; F Gölfert; R H Funk
Journal:  Med Biol Eng Comput       Date:  1999-09       Impact factor: 2.602

2.  Hypoxic cellular deterioration and its prevention by the amino acid taurine in a transplantation model with renal tubular cells (LLC-PK1).

Authors:  P Wingenfeld; T Minor; U Gehrmann; S Strübind; W Isselhard; D Michalk
Journal:  In Vitro Cell Dev Biol Anim       Date:  1995 Jul-Aug       Impact factor: 2.416

3.  Isoprenaline-stimulated differential adrenergic response of K+ channels in skeletal muscle under hypokalaemic conditions.

Authors:  R J Geukes Foppen; J Siegenbeek Van Heukelom
Journal:  Pflugers Arch       Date:  2003-03-15       Impact factor: 3.657

4.  A transparent cell-culture microchamber with a variably controlled concentration gradient generator and flow field rectifier.

Authors:  Ji-Yen Cheng; Meng-Hua Yen; Ching-Te Kuo; Tai-Horng Young
Journal:  Biomicrofluidics       Date:  2008-06-17       Impact factor: 2.800

5.  The effect of L-type Ca2+ channel blockers on anoxia-induced increases in intracellular Ca2+ concentration in rabbit proximal tubule cells in primary culture.

Authors:  U M Rose; R J Bindels; A Vis; J W Jansen; C H Van Os
Journal:  Pflugers Arch       Date:  1993-06       Impact factor: 3.657

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.