Literature DB >> 21324667

An electrochemical biosensor for fructosyl valine for glycosylated hemoglobin detection based on core-shell magnetic bionanoparticles modified gold electrode.

Sheetal Chawla1, Chandra Shekhar Pundir.   

Abstract

A high-performance amperometric fructosyl valine (FV) biosensor was developed, based on immobilization of fructosyl amino-acid oxidase (FAO) on core-shell magnetic bionanoparticles modified gold electrode. Chitosan was used to introduce amino groups onto the surface of core-shell magnetic bionanoparticles (MNPs). With FAO as an enzyme model, a new fructosyl valine biosensor was fabricated. The biosensor showed optimum response, when operated at 50 mVs(-1) in 0.1M potassium phosphate buffer, pH 7.5 and 35°C. The biosensor exhibited excellent sensitivity [the detection limit is down to 0.1mM for FV], fast response time (less than 4s), wide linear range (from 0 to 2mM). Analytical recovery of added FV was 95.00-98.50%. Within batch and between batch coefficients of variation were <2.58% and <5.63%, respectively. The enzyme electrode was used 250 times over 3 months, when stored at 4°C.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21324667     DOI: 10.1016/j.bios.2011.01.021

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin.

Authors:  Zhikun Zhan; Yang Li; Yuliang Zhao; Hongyu Zhang; Zhen Wang; Boya Fu; Wen Jung Li
Journal:  Biosensors (Basel)       Date:  2022-04-08

Review 2.  Electrochemical biosensors based on ferroceneboronic Acid and its derivatives: a review.

Authors:  Baozhen Wang; Shigehiro Takahashi; Xiaoyan Du; Jun-Ichi Anzai
Journal:  Biosensors (Basel)       Date:  2014-07-30

Review 3.  Current Status of HbA1c Biosensors.

Authors:  Hua Lin; Jun Yi
Journal:  Sensors (Basel)       Date:  2017-08-04       Impact factor: 3.576

Review 4.  Recent Progress in Electrochemical HbA1c Sensors: A Review.

Authors:  Baozhen Wang; Jun-Ichi Anzai
Journal:  Materials (Basel)       Date:  2015-03-17       Impact factor: 3.623

5.  Gold Nanostar Colorimetric Detection of Fructosyl Valine as a Potential Future Point of Care Biosensor Candidate for Glycated Haemoglobin Detection.

Authors:  Danielle Wingrove Mulder; Masauso Moses Phiri; Barend Christiaan Vorster
Journal:  Biosensors (Basel)       Date:  2019-08-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.