Literature DB >> 2132243

Comparative evaluation of bone marrow aspirate particle smears, imprints and biopsy sections.

B D Sabharwal1, V Malhotra, S Aruna, R Grewal.   

Abstract

Comparative evaluation of bone marrow aspirate particle smears, imprints and biopsy sections was done on 30 haematological problems. Core needle biopsy of the bone marrow is a safe and useful procedure. It is a valuable diagnostic aid for measurement of marrow cellularity, metastatic tumours and fibrosis. It should not be taken as a substitute for examination of the marrow by aspiration smear but is a complementary procedure which affords several advantages. Bone marrow biopsy was of maximum utility in myelofibrosis which was diagnosed on biopsy alone. There were three additional cases with normal bone marrow aspiration in which specific diagnosis could only be made from bone marrow biopsy sections. New methodologies i.e. plastic embedding and semi thin sections of undecalcified bone marrow, can be expected to improve the cytological details of tissue obtained by biopsy. Imprint preparations obtained from biopsy can be useful in patients of malignancy but we have found them to be of limited value except in cases of dry tap.

Entities:  

Mesh:

Year:  1990        PMID: 2132243

Source DB:  PubMed          Journal:  J Postgrad Med        ISSN: 0022-3859            Impact factor:   1.476


  7 in total

1.  Comparative evaluation of simultaneous bone marrow aspiration and bone marrow biopsy: an institutional experience.

Authors:  Pampa Ch Toi; Renu G'boy Varghese; Ramji Rai
Journal:  Indian J Hematol Blood Transfus       Date:  2010-10-06       Impact factor: 0.900

2.  Diagnosis of unknown nonhematological tumors by bone marrow biopsy: a retrospective analysis of 10,112 samples.

Authors:  Li Xiao; Song Luxi; Tao Ying; Liu Yizhi; Wu Lingyun; Pu Quan
Journal:  J Cancer Res Clin Oncol       Date:  2008-10-28       Impact factor: 4.553

Review 3.  A pathologist's perspective on bone marrow aspiration and biopsy: I. Performing a bone marrow examination.

Authors:  Roger S Riley; Thomas F Hogan; Dawn R Pavot; Robert Forysthe; Davis Massey; Eileen Smith; Lou Wright; Jonathan M Ben-Ezra
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

4.  Comparison of bone marrow aspirate cytology, touch imprint cytology and trephine biopsy for bone marrow evaluation.

Authors:  Smita Chandra; Harish Chandra
Journal:  Hematol Rep       Date:  2011-10-21

5.  Comparative evaluation of bone marrow aspirate with trephine biopsy in hematological disorders and determination of optimum trephine length in lymphoma infiltration.

Authors:  Surbhi Goyal; Usha Rani Singh; Usha Rusia
Journal:  Mediterr J Hematol Infect Dis       Date:  2014-01-02       Impact factor: 2.576

Review 6.  Second-Generation Tyrosine Kinase Inhibitors (Tki) as Salvage Therapy for Resistant or Intolerant Patients to Prior TKIs.

Authors:  Massimo Breccia; Giuliana Alimena
Journal:  Mediterr J Hematol Infect Dis       Date:  2014-01-02       Impact factor: 2.576

7.  Comparison of bone marrow aspiration cytology with bone marrow trephine biopsy histopathology: An observational study.

Authors:  Meenu Gilotra; Monika Gupta; Sunita Singh; Rajeev Sen
Journal:  J Lab Physicians       Date:  2017 Jul-Sep
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.