Literature DB >> 21321842

Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography.

F Piscaglia1, V Salvatore, R Di Donato, M D'Onofrio, S Gualandi, A Gallotti, E Peri, A Borghi, F Conti, G Fattovich, E Sagrini, A Cucchetti, P Andreone, L Bolondi.   

Abstract

PURPOSE: VirtualTouch is a new technique recently proposed to evaluate liver stiffness during B-mode ultrasonography. The goal of the present study was to analyze the diagnostic accuracy of VirtualTouch in the diagnosis of cirrhosis and its correlation with transient elastography (Fibroscan).
MATERIALS AND METHODS: A total of 133 patients with chronic liver disease were enrolled. 90 of 133 underwent VirtualTouch and transient elastography and 70 patients assessed with VirtualTouch were submitted to liver biopsy. Stiffness was assessed by both techniques in the right liver lobe. The diagnostic accuracy for cirrhosis was first assessed in the 90 patients submitted to transient elastography with > 13 kPa (47 % of patients) as diagnostic for cirrhosis values. The best cut-off for cirrhosis with VirtualTouch was then tested in the 70 patients with biopsy (cirrhosis in 38 % of patients). 41 patients were assessed by VirtualTouch by two different operators.
RESULTS: The VirtualTouch values in controls, chronic hepatitis and cirrhosis were respectively 113, 147 and 255 cm/sec. The AUROC of liver VirtualTouch for the diagnosis of cirrhosis (reference Fibroscan) was 0.941 with 175 cm/sec as the best cut-off (sensitivity 93.0 %; specificity 85.1 %). VirtualTouch confirmed good performance also in patients with bioptic diagnosis of cirrhosis (AUROC 0.908, sensitivity 81.5 %, specificity 88.4 %,). The correlation of VirtualTouch with transient elastography was strict (r = 0.891) and the correlation in VirtualTouch measurements between two operators was also good (r = 0.874).
CONCLUSION: VirtualTouch is able to identify the presence of cirrhosis with good accuracy, shows good interobserver reproducibility and the correlation of its values with those obtained by transient elastography with Fibroscan is good. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2011        PMID: 21321842     DOI: 10.1055/s-0029-1245948

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  31 in total

1.  Acoustic radiation force-based elasticity imaging methods.

Authors:  Mark L Palmeri; Kathryn R Nightingale
Journal:  Interface Focus       Date:  2011-06-08       Impact factor: 3.906

Review 2.  Liver elastography, comments on EFSUMB elastography guidelines 2013.

Authors:  Xin-Wu Cui; Mireen Friedrich-Rust; Chiara De Molo; Andre Ignee; Dagmar Schreiber-Dietrich; Christoph F Dietrich
Journal:  World J Gastroenterol       Date:  2013-10-14       Impact factor: 5.742

3.  Diagnostic utility of Acoustic Radiation Force Impulse (ARFI) imaging in primary Sjoegren`s syndrome.

Authors:  Andreas Knopf; Benedikt Hofauer; Klaus Thürmel; Reinhard Meier; Konrad Stock; Murat Bas; Naglaa Manour
Journal:  Eur Radiol       Date:  2015-04-11       Impact factor: 5.315

4.  Non invasive tools for the diagnosis of liver cirrhosis.

Authors:  Maurizio Soresi; Lydia Giannitrapani; Melchiorre Cervello; Anna Licata; Giuseppe Montalto
Journal:  World J Gastroenterol       Date:  2014-12-28       Impact factor: 5.742

Review 5.  Acoustic radiation force elasticity imaging in diagnostic ultrasound.

Authors:  Joshua R Doherty; Gregg E Trahey; Kathryn R Nightingale; Mark L Palmeri
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-04       Impact factor: 2.725

6.  Ultrasound evaluation of liver fibrosis: preliminary experience with acoustic structure quantification (ASQ) software.

Authors:  Paolo Ricci; Chiara Marigliano; Vito Cantisani; Andrea Porfiri; Andrea Marcantonio; Pietro Lodise; Ugo D'Ambrosio; Giancarlo Labbadia; Elena Maggini; Ester Mancuso; Giovanna Panzironi; Mattia Di Segni; Caterina Furlan; Raffaele Masciangelo; Gloria Taliani
Journal:  Radiol Med       Date:  2013-06-26       Impact factor: 3.469

7.  Effect of liposomal local therapy on salivary glands in acoustic radiation force impulse imaging in Sjögren's syndrome.

Authors:  Benedikt Hofauer; Naglaa Mansour; Clemens Heiser; Ulrich Straßen; Murat Bas; Andreas Knopf
Journal:  Clin Rheumatol       Date:  2016-08-29       Impact factor: 2.980

8.  Combined acoustic radiation force impulse, aminotransferase to platelet ratio index and Forns index assessment for hepatic fibrosis grading in hepatitis B.

Authors:  Chang-Feng Dong; Jia Xiao; Ling-Bo Shan; Han-Ying Li; Yong-Jia Xiong; Gui-Lin Yang; Jing Liu; Si-Min Yao; Sha-Xi Li; Xiao-Hua Le; Jing Yuan; Bo-Ping Zhou; George L Tipoe; Ying-Xia Liu
Journal:  World J Hepatol       Date:  2016-05-18

Review 9.  Non-invasive diagnosis of liver fibrosis in chronic hepatitis C.

Authors:  Leonardo de Lucca Schiavon; Janaína Luz Narciso-Schiavon; Roberto José de Carvalho-Filho
Journal:  World J Gastroenterol       Date:  2014-03-21       Impact factor: 5.742

Review 10.  Noninvasive diagnosis of cirrhosis: a review of different imaging modalities.

Authors:  Riccardo De Robertis; Mirko D'Onofrio; Emanuele Demozzi; Stefano Crosara; Stefano Canestrini; Roberto Pozzi Mucelli
Journal:  World J Gastroenterol       Date:  2014-06-21       Impact factor: 5.742

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.