Literature DB >> 21321387

High-energy radiation monitoring based on radio-fluorogenic co-polymerization II: fixed fluorescent images of collimated x-ray beams using an RFCP gel.

J M Warman1, L H Luthjens, M P de Haas.   

Abstract

We have produced an optically clear, close to water-equivalent gel that is radio-fluorogenic, i.e. fluoresces in UV light after exposure to high-energy radiation. Its potential as a 2D and 3D dosimetric medium is demonstrated by fixed fluorescent images of the cross-section, track and intersection of collimated (10 × 10 or 5 × 5 mm(2)) 205 kVp x-ray beams. The images, produced by doses on the order of 10 Gy, are formed instantaneously and can be digitally recorded and scanned with a spatial resolution on the order of 0.1 mm. No loss of spatial resolution occurs on standing under ambient conditions for at least 3 days.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21321387     DOI: 10.1088/0031-9155/56/5/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Features of PABIGnx 3D Polymer Gel as an Ionising Radiation Dosimeter.

Authors:  Marek Kozicki; Malwina Jaszczak; Piotr Maras
Journal:  Materials (Basel)       Date:  2022-03-31       Impact factor: 3.623

2.  Characterization of a Radiofluorogenic Polymer for Low-Energy Electron Beam Penetration Depth Visualization.

Authors:  Magdalena Maria Skowyra; Christina Ankjærgaard; Liyun Yu; Lars René Lindvold; Anne Ladegaard Skov; Arne Miller
Journal:  Polymers (Basel)       Date:  2022-03-03       Impact factor: 4.329

3.  Sensitivity enhancement of DHR123 radio-fluorogenic nanoclay gel dosimeter by incorporating surfactants and halogenides.

Authors:  Anri Mochizuki; Takuya Maeyama; Yusuke Watanabe; Shinya Mizukami
Journal:  RSC Adv       Date:  2020-08-04       Impact factor: 4.036

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

5.  Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy.

Authors:  Piotr Maras; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

6.  FluoroTome 1: An Apparatus for Tomographic Imaging of Radio-Fluorogenic (RFG) Gels.

Authors:  John M Warman; Matthijs P de Haas; Leonard H Luthjens; Tiantian Yao; Julia Navarro-Campos; Sölen Yuksel; Jan Aarts; Simon Thiele; Jacco Houter; Wilco In Het Zandt
Journal:  Polymers (Basel)       Date:  2019-10-23       Impact factor: 4.329

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.