BACKGROUND AND PURPOSE: To compare left-sided whole breast conventional and intensity-modulated radiotherapy (IMRT) treatment planning techniques. MATERIALS AND METHODS: Treatment plans were created for 10 consecutive patients. Three-dimensional conformal radiotherapy (3DCRT), forward-planned IMRT (for-IMRT), and inverse-planned IMRT (inv-IMRT) used two tangent beams. For-IMRT utilized up to four segments per beam. For helical tomotherapy (HT) plans, beamlet entrance and/or exit to critical structures was blocked. Topotherapy plans, which used static gantry angles with simultaneous couch translation and inverse-planned intensity modulation, used two tangent beams. Plans were normalized to 50Gy to 95% of the retracted PTV. RESULTS: Target max doses were reduced with for-IMRT compared to 3DCRT, which were further reduced with HT, topotherapy, and inv-IMRT. HT resulted in lowest heart and ipsilateral lung max doses, but had higher mean doses. Inv-IMRT and topotherapy reduced ipsilateral lung mean and max doses compared to 3DCRT and for-IMRT. CONCLUSIONS: All modalities evaluated provide adequate coverage of the intact breast. HT, topotherapy, and inv-IMRT can reduce high doses to the target and normal tissues, although HT results in increased low doses to large volume of normal tissue. For-IMRT improves target homogeneity compared with 3DCRT, but to a lesser degree than the inverse-planned modalities.
BACKGROUND AND PURPOSE: To compare left-sided whole breast conventional and intensity-modulated radiotherapy (IMRT) treatment planning techniques. MATERIALS AND METHODS: Treatment plans were created for 10 consecutive patients. Three-dimensional conformal radiotherapy (3DCRT), forward-planned IMRT (for-IMRT), and inverse-planned IMRT (inv-IMRT) used two tangent beams. For-IMRT utilized up to four segments per beam. For helical tomotherapy (HT) plans, beamlet entrance and/or exit to critical structures was blocked. Topotherapy plans, which used static gantry angles with simultaneous couch translation and inverse-planned intensity modulation, used two tangent beams. Plans were normalized to 50Gy to 95% of the retracted PTV. RESULTS: Target max doses were reduced with for-IMRT compared to 3DCRT, which were further reduced with HT, topotherapy, and inv-IMRT. HT resulted in lowest heart and ipsilateral lung max doses, but had higher mean doses. Inv-IMRT and topotherapy reduced ipsilateral lung mean and max doses compared to 3DCRT and for-IMRT. CONCLUSIONS: All modalities evaluated provide adequate coverage of the intact breast. HT, topotherapy, and inv-IMRT can reduce high doses to the target and normal tissues, although HT results in increased low doses to large volume of normal tissue. For-IMRT improves target homogeneity compared with 3DCRT, but to a lesser degree than the inverse-planned modalities.
Authors: M L Sautter-Bihl; F Sedlmayer; W Budach; J Dunst; P Feyer; R Fietkau; W Haase; W Harms; C Rödel; R Souchon; F Wenz; R Sauer Journal: Strahlenther Onkol Date: 2012-06 Impact factor: 3.621
Authors: S Schönecker; C Heinz; M Söhn; W Haimerl; S Corradini; M Pazos; C Belka; H Scheithauer Journal: Strahlenther Onkol Date: 2016-09-08 Impact factor: 3.621
Authors: Sadek A Nehmeh; Joseph J Fox; Jazmin Schwartz; Åse M Ballangrud; Heiko Schöder; Yize Zhao; Henry W Strauss; Anthony Yu; Dipti Gupta; Simon N Powell; Alice Y Ho Journal: Clin Imaging Date: 2020-08-27 Impact factor: 1.605