Literature DB >> 21315890

A sensitive, rapid and inexpensive way to assay pesticide toxicity based on electrochemical biosensor.

Daming Yong1, Chang Liu, Dengbin Yu, Shaojun Dong.   

Abstract

We reported a rapid toxicity assay method using electrochemical biosensor for pesticides, Escherichia coli (E. coli) was taken as a model microorganism for test. In this method, we adopted ferricyanide instead of natural electron acceptor O(2), and then microbial oxidation was substantially accelerated. Toxicity assays measured the effect of toxic materials on the metabolic activity of microorganisms. The current signal of ferrocyanide produced from the metabolism was proven to be directly related to the toxicity, which could be amplified by ultramicroelectrode array (UMEA). The ratio of the electrochemical signals, recorded in the presence and absence of toxin, provided an index of inhibition. Accordingly, a direct toxicity assessment (DTA) based on chronoamperometry was proposed to detect the effect of toxic chemicals on microorganisms. 3,5-Dichlorophenol (DCP) was taken as the reference toxicant, its IC50 was estimated to be 8.0mg/L. Three pesticides were examined using this method. IC50 values of 6.5mg/L for Ametryn, 22 mg/L for Fenamiphos and 5.7 mg/L for Endosulfan were determined and in line with EC50 values reported in the literature. Atomic force microscopy (AFM) was also used for morphology characterization of E. coli induced by three pesticides. These results confirmed the present electrochemical method used is reliable. In addition, the electrochemical method is a sensitive, rapid and inexpensive way for toxicity assays of pesticides.
Copyright © 2011. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21315890     DOI: 10.1016/j.talanta.2010.11.012

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A novel construct of an electrochemical acetylcholinesterase biosensor for the investigation of malathion sensitivity to three different insect species using a NiCr2O4/g-C3N4 composite integrated pencil graphite electrode.

Authors:  Sehrish Bilal; Muhammad Nasir; M Mudassir Hassan; Muhammad Fayyaz Ur Rehman; Amtul Jamil Sami; Akhtar Hayat
Journal:  RSC Adv       Date:  2022-06-07       Impact factor: 4.036

2.  Bio-sensing of cadmium(II) ions using Staphylococcus aureus.

Authors:  Jiri Sochor; Ondrej Zitka; David Hynek; Eva Jilkova; Ludmila Krejcova; Libuse Trnkova; Vojtech Adam; Jaromir Hubalek; Jindrich Kynicky; Radimir Vrba; Rene Kizek
Journal:  Sensors (Basel)       Date:  2011-11-08       Impact factor: 3.576

3.  Hydrodynamic chronoamperometry for probing kinetics of anaerobic microbial metabolism--case study of Faecalibacterium prausnitzii.

Authors:  Antonin Prévoteau; Annelies Geirnaert; Jan B A Arends; Sylvain Lannebère; Tom Van de Wiele; Korneel Rabaey
Journal:  Sci Rep       Date:  2015-07-01       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.