Literature DB >> 21315530

Comparison of automated 4-chamber cardiac views versus axial views for measuring right ventricular enlargement in patients with suspected pulmonary embolism.

R Wittenberg1, J W van Vliet, B Ghaye, J F Peters, C M Schaefer-Prokop, E Coche.   

Abstract

PURPOSE: Compare the right ventricle to left ventricle (RV/LV) diameter ratio obtained from axial pulmonary CT angiograms (CTPA) with those derived from automatically generated 4-chamber (4-CH) reformats in patients with suspected pulmonary embolism (PE).
METHODS: In this institutional review board-approved study we included 120 consecutive non ECG-gated CTPA from 3 institutions (mean age 60 ± 16 years; 71 women). Twenty 64-slice CTPA with PE and 20 without PE were selected per institution. For each patient the RV/LV diameter ratio was obtained from both axial CTPA images and automatically generated 4-CH reformats. Measurements were performed twice in two separated sessions by 2 experienced radiologists and 2 residents. The differences between the measurements on both views were evaluated.
RESULTS: The 4-CH view was successfully obtained in 113 patients. The mean axial and 4-CH diameter ratios were comparable for three of the four readers (p = 0.56, p = 0.13, p = 0.08). Although the mean diameters (1.0 and 1.03 respectively) for one resident were significantly different (p = 0.013), the difference of 0.03 seems negligible in clinical routine. Three readers achieved equally high intra-reader agreements with both measurements (ICCs of 0.94, 0.95 and 0.96), while one reader showed a different variability with ICCs of 0.96 for the axial view and 0.91 for the 4-CH view. The inter-reader agreement was equally high for both measurement types with ICCs of 0.95 and 0.94, respectively.
CONCLUSION: In patients with suspected PE, RV/LV diameters ratio can be measured with the same reproducibility and accuracy using an automatically generated 4-CH view compared to the axial view.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21315530     DOI: 10.1016/j.ejrad.2011.01.041

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  6 in total

1.  Right ventricular enlargement in acute pulmonary embolism derived from CT pulmonary angiography.

Authors:  Kanako K Kumamaru; Michael T Lu; Sanaz Ghaderi Niri; Andetta R Hunsaker
Journal:  Int J Cardiovasc Imaging       Date:  2013-03       Impact factor: 2.357

2.  Feasibility of Coronary CT Angiography-derived Left Ventricular Long-Axis Shortening as an Early Marker of Ventricular Dysfunction in Transcatheter Aortic Valve Replacement.

Authors:  Gilberto J Aquino; Josua A Decker; U Joseph Schoepf; Landin Carson; Namrata Paladugu; Basel Yacoub; Verena Brandt; Anna Lena Emrich; Florian Schwarz; Jeremy R Burt; Richard Bayer; Akos Varga-Szemes; Tilman Emrich
Journal:  Radiol Cardiothorac Imaging       Date:  2022-06-30

3.  Automated axial right ventricle to left ventricle diameter ratio computation in computed tomography pulmonary angiography.

Authors:  Germán González; Daniel Jiménez-Carretero; Sara Rodríguez-López; Kanako K Kumamaru; Elizabeth George; Raúl San José Estépar; Frank J Rybicki; Maria J Ledesma-Carbayo
Journal:  PLoS One       Date:  2015-05-22       Impact factor: 3.240

4.  Accuracy and reproducibility of CT right-to-left ventricular diameter measurement in patients with acute pulmonary embolism.

Authors:  Yvonne M Ende-Verhaar; Lucia J M Kroft; Inge C M Mos; Menno V Huisman; Frederikus A Klok
Journal:  PLoS One       Date:  2017-11-28       Impact factor: 3.240

5.  Acute Pulmonary Embolism Severity Assessment Evaluated with Dual Energy CT Perfusion Compared to Conventional CT Angiographic Measurements.

Authors:  Samir Jawad; Peter Sommer Ulriksen; Anna Kalhauge; Kristoffer Lindskov Hansen
Journal:  Diagnostics (Basel)       Date:  2021-03-11

6.  Cardiothoracic CT: one-stop-shop procedure? Impact on the management of acute pulmonary embolism.

Authors:  Pauline J Abrahams-van Doorn; Ieneke J C Hartmann
Journal:  Insights Imaging       Date:  2011-08-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.