Z Nüssgens1, B Czerwonka, P Roggenkämper.
Abstract
The New Lang-II stereopsis test employs, as compared to the Lang-I test, smaller disparities and a less dense arrangement of random dots. In 162 subjects the authors comparatively evaluated the results of the Lang-I and Lang-II tests. Ninety percent of subjects with normal binocular vision passed both tests without making any mistake (n = 127). However, about 70% of patients with microstrabismus failed both tests (n = 35). Little difference was found between the results of both tests.Entities:
Year: 1993 PMID: 21314501 DOI: 10.3109/09273979309087720
Source DB: PubMed Journal: Strabismus ISSN: 0927-3972