Abstract

STUDY
DESIGN: A retrospective clinical study.
OBJECTIVE: To introduce a novel method of pedicle screw placement for extremely small thoracic pedicles in scoliosis and evaluate the safety and accuracy of the method. SUMMARY OF BACKGROUND DATA: Few studies have provided technical guidelines for screw placement in patients with extremely small thoracic pedicles in scoliosis.
METHODS: In a severely rotated scoliotic spine, thoracic pedicle screw placement is challenging, and particularly more so for extremely small pedicles with a diameter less than 2 mm. The authors introduced a novel method of screw placement for these small pedicles: "medial margin targeting method."The C-arm fluoroscope is rotated until a true PA image of the rotated vertebral body is acquired and both pedicle shadows are symmetrically visualized en face. In extremely small pedicles, pedicle shadows appear as long, slender ellipses or lines. An imaginary pedicle outline is presumed with the elliptical or linear shadows being the medial margin of the pedicle. The entry point of a screw can be made at the 10-o'clock or 2-o'clock position on the presumed pedicle outline, and the screw can be safely inserted targeting the presumed medial margin with caution not to penetrate the medial cortex using the guidance of a true PA image. This is a kind of extrapedicular screw placement method.The safety and accuracy of this method were evaluated in 97 patients with scoliosis who had undergone posterior correction and instrumentation using postoperative computed tomography scans. A total of 1634 pedicle screws were inserted into thoracic pedicles, 128 of them (7.8%) being extremely small pedicles with a diameter less than 2 mm.
RESULTS: Among 128 extremely small thoracic pedicles with a diameter less than 2 mm, one screw (0.8%) violated the medial cortex and 22 screws (17.6%) violated the anterior cortex of the vertebral body. No screws violated the lateral cortex of the pedicle-rib unit. There were no complications associated with screw misplacement.
CONCLUSION: In scoliosis patients with extremely small thoracic pedicles, our pedicle screw placement method targeting the presumed medial margin in a true PA C-arm image allows easy application with accuracy and safety, which would not possible by any other method described so far.

Entities:  

Mesh:

Year:  2011        PMID: 21304429     DOI: 10.1097/BRS.0b013e3181ffeea2

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  4 in total

Review 1.  Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review.

Authors:  Ahmed A Aoude; Maryse Fortin; Rainer Figueiredo; Peter Jarzem; Jean Ouellet; Michael H Weber
Journal:  Eur Spine J       Date:  2015-03-07       Impact factor: 3.134

2.  Accuracy of cannulated pedicle screw versus conventional pedicle screw for extra-pedicular screw placement in dysplastic pedicles without cancellous channel in adolescent idiopathic scoliosis: a computerized tomography (CT) analysis.

Authors:  Chee Kean Lee; Chris Yin Wei Chan; Siti Mariam Abd Gani; Mun Keong Kwan
Journal:  Eur Spine J       Date:  2017-08-17       Impact factor: 3.134

3.  Is the Combination of Convex Compression for the Proximal Thoracic Curve and Concave Distraction for the Main Thoracic Curve Using Separate-rod Derotation Effective for Correcting Shoulder Balance and Thoracic Kyphosis?

Authors:  Choon Sung Lee; Sehan Park; Dong-Ho Lee; Chang Ju Hwang; Jae Hwan Cho; Jae Woo Park; Kun-Bo Park
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

4.  Thoracic Pedicle Morphometry of Dry Vertebral Columns in Relation to Trans-Pedicular Fixation: A Cross-Sectional Study From Central India.

Authors:  Virendra Verma; John A Santoshi; Vaibhav Jain; Manmohan Patel; Manish Dwivedi; Manoj Nagar; Rajkumar Selvanayagam; Dharm Pal
Journal:  Cureus       Date:  2020-05-16
  4 in total