Literature DB >> 21302800

An algorithm for fast beam angle selection in intensity modulated radiotherapy.

R Vaitheeswaran1, V K Sathiya Narayanan, Janhavi R Bhangle, Amit Nirhali, Namitha Kumar, Sumit Basu, Vikram Maiya.   

Abstract

PURPOSE: This article aims to introduce a novel algorithm for fast beam angle selection in intensity modulated radiotherapy (IMRT).
METHODS: The algorithm models the optimization problem as a beam angle ranking problem and chooses suitable beam angles according to their rank. A new parameter called "beam intensity profile perturbation score (BIPPS)" is used for ranking the beam angles. The BIPPS-based beam angle ranking implicitly accounts for the dose-volume effects of the involved structures. A simulated phantom case with obvious optimal beam angles is used to verify the validity of the presented technique. In addition, the efficiency of the algorithm was examined in three clinical cases (prostate, pancreas, and head and neck) in terms of DVH and dose distribution. In all cases, the judgment of the algorithm's efficiency was based on the comparison between plans with equidistant beams (equal-angle-plan) and plans with beams obtained using the algorithm (suitable-angle-plan).
RESULTS: It is observed from the study that the beam angle ranking function over BIPPS instantly picks up a suitable set of beam angles for a specific case. It takes only about 15 min for choosing the suitable beam angles even for the most complicated cases. The DVHs and dose distributions confirm that the proposed algorithm can efficiently reduce the mean or maximum dose to OARs, while guaranteeing the target coverage and dose uniformity. On the average, about 17% reduction in the mean dose to critical organs, such as rectum, bladder, kidneys and parotids, is observed. Also, about 12% (averaged) reduction in the maximum dose to critical organs (spinal cord) is observed in the clinical cases presented in this study.
CONCLUSIONS: This study demonstrates that the algorithm can be effectively applied to IMRT scenarios to get fast and case specific beam angle configurations.

Entities:  

Mesh:

Year:  2010        PMID: 21302800     DOI: 10.1118/1.3517866

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Simultaneous beam sampling and aperture shape optimization for SPORT.

Authors:  Masoud Zarepisheh; Ruijiang Li; Yinyu Ye; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

2.  A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning.

Authors:  H H Zhang; S Gao; W Chen; L Shi; W D D'Souza; R R Meyer
Journal:  Phys Med Biol       Date:  2013-03-21       Impact factor: 3.609

3.  An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors.

Authors:  V K Sathiya Narayanan; R Vaitheeswaran; Janhavi R Bhangle; Sumit Basu; Vikram Maiya; Bhooshan Zade
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

4.  The Scatter Search Based Algorithm for Beam Angle Optimization in Intensity-Modulated Radiation Therapy.

Authors:  Ali Ghanbarzadeh; Majid Pouladian; Ali Shabestani Monfared; Seied Rabi Mahdavi
Journal:  Comput Math Methods Med       Date:  2018-06-03       Impact factor: 2.238

5.  Beam selection for stereotactic ablative radiotherapy using Cyberknife with multileaf collimation.

Authors:  James L Bedford; Peter Ziegenhein; Simeon Nill; Uwe Oelfke
Journal:  Med Eng Phys       Date:  2018-12-20       Impact factor: 2.242

6.  Determination of optimal number of beams in direct machine parameter optimization-based intensity modulated radiotherapy for head and neck cases.

Authors:  Vaitheeswaran Ranganathan; K J Maria Das
Journal:  J Med Phys       Date:  2016 Apr-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.