Direct three-dimensional coherently scattered x-ray microtomography.

Congwu Cui1, Steven M Jorgensen, Diane R Eaker, Erik L Ritman.   

Abstract

PURPOSE: It has been shown that coherently scattered x rays can be used to discriminate and identify specific components in a mixture of low atomic weight materials. The authors demonstrated a new method of doing coherently scattered x-ray tomography with a thin sheet of x ray.
METHODS: A collimated x-ray fan-beam, a parallel polycapillary collimator, and a phantom consisting of several biocompatible materials of low attenuation-based contrast were used to investigate the feasibility of the method. Because of the particular experimental setup, only the phantom translation perpendicular to the x-ray beam is needed and, thus, there is no need of Radon-type tomographic reconstruction, except for the correction of the attenuation to the primary and scattered x rays, which was performed by using a conventional attenuation-based tomographic image data set. The coherent scatter image contrast changes with momentum transfer among component materials in the specimen were investigated with multiple x-ray sources with narrow bandwidth spectra generated with anode and filter combinations of Cu/Ni (8 keV), Mo/Zr (18 keV), and Ag/Pd (22 keV) and at multiple scatter angles by orienting the detector and polycapillary collimator at different angles to the illuminating x ray.
RESULTS: The contrast among different materials changes with the x-ray source energy and the angle at which the image was measured. The coherent scatter profiles obtained from the coherent scatter images are consistent with the published results.
CONCLUSIONS: This method can be used to directly generate the three-dimensional coherent scatter images of small animal, biopsies, or other small objects with low atomic weight biological or similar synthetic materials with low attenuation contrast. With equipment optimized, submillimeter spatial resolution may be achieved.

Entities:  

Mesh:

Year:  2010        PMID: 21302788      PMCID: PMC3000860          DOI: 10.1118/1.3517194

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  X-ray scattering from human breast tissues and breast-equivalent materials.

Authors:  M E Poletti; D Gonçalves; I Mazzaro
Journal:  Phys Med Biol       Date:  2002-01-07       Impact factor: 3.609

2.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

3.  A reconstruction algorithm for coherent scatter computed tomography based on filtered back-projection.

Authors:  U van Stevendaal; J P Schlomka; A Harding; M Grass
Journal:  Med Phys       Date:  2003-09       Impact factor: 4.071

4.  Bone-composition imaging using coherent-scatter computed tomography: assessing bone health beyond bone mineral density.

Authors:  Deidre L Batchelar; Melanie T M Davidson; Waldemar Dabrowski; Ian A Cunningham
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

5.  Three-dimensional imaging of vasculature and parenchyma in intact rodent organs with X-ray micro-CT.

Authors:  S M Jorgensen; O Demirkaya; E L Ritman
Journal:  Am J Physiol       Date:  1998-09

6.  Tomographic imaging of the angular-dependent coherent-scatter cross section.

Authors:  M S Westmore; A Fenster; I A Cunningham
Journal:  Med Phys       Date:  1997-01       Impact factor: 4.071

7.  X-ray diffraction measurements of some plastic materials and body tissues.

Authors:  J Kosanetzky; B Knoerr; G Harding; U Neitzel
Journal:  Med Phys       Date:  1987 Jul-Aug       Impact factor: 4.071

8.  High resolution three-dimensional visualization and characterization of coronary atherosclerosis in vitro by synchrotron radiation x-ray microtomography and highly localized x-ray diffraction.

Authors:  Hua Jin; Kyungmin Ham; Julia Y Chan; Leslie G Butler; Richard L Kurtz; Serigne Thiam; James W Robinson; Rezik A Agbaria; Isiah M Warner; Richard E Tracy
Journal:  Phys Med Biol       Date:  2002-12-21       Impact factor: 3.609

9.  Structural characterization of the human cerebral myelin sheath by small angle x-ray scattering.

Authors:  M De Felici; R Felici; C Ferrero; A Tartari; M Gambaccini; S Finet
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

10.  Material-specific analysis using coherent-scatter imaging.

Authors:  Deidre L Batchelar; Ian A Cunningham
Journal:  Med Phys       Date:  2002-08       Impact factor: 4.071

View more
  3 in total

1.  Small-angle scatter tomography with a photon-counting detector array.

Authors:  Shuo Pang; Zheyuan Zhu; Ge Wang; Wenxiang Cong
Journal:  Phys Med Biol       Date:  2016-04-15       Impact factor: 3.609

2.  Compressive sensing in medical imaging.

Authors:  Christian G Graff; Emil Y Sidky
Journal:  Appl Opt       Date:  2015-03-10       Impact factor: 1.980

3.  In vivo X-Ray Phase Imaging.

Authors:  Erik L Ritman
Journal:  EBioMedicine       Date:  2015-09-07       Impact factor: 8.143

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.