Reconstruction of a cone-beam CT image via forward iterative projection matching.

R Scott Brock1, Alen Docef, Martin J Murphy.   

Abstract

PURPOSE: To demonstrate the feasibility of reconstructing a cone-beam CT (CBCT) image by deformably altering a prior fan-beam CT (FBCT) image such that it matches the anatomy portrayed in the CBCT projection data set.
METHODS: A prior FBCT image of the patient is assumed to be available as a source image. A CBCT projection data set is obtained and used as a target image set. A parametrized deformation model is applied to the source FBCT image, digitally reconstructed radiographs (DRRs) that emulate the CBCT projection image geometry are calculated and compared to the target CBCT projection data, and the deformation model parameters are adjusted iteratively until the DRRs optimally match the CBCT projection data set. The resulting deformed FBCT image is hypothesized to be an accurate representation of the patient's anatomy imaged by the CBCT system. The process is demonstrated via numerical simulation. A known deformation is applied to a prior FBCT image and used to create a synthetic set of CBCT target projections. The iterative projection matching process is then applied to reconstruct the deformation represented in the synthetic target projections; the reconstructed deformation is then compared to the known deformation. The sensitivity of the process to the number of projections and the DRR/CBCT projection mismatch is explored by systematically adding noise to and perturbing the contrast of the target projections relative to the iterated source DRRs and by reducing the number of projections.
RESULTS: When there is no noise or contrast mismatch in the CBCT projection images, a set of 64 projections allows the known deformed CT image to be reconstructed to within a nRMS error of 1% and the known deformation to within a nRMS error of 7%. A CT image nRMS error of less than 4% is maintained at noise levels up to 3% of the mean projection intensity, at which the deformation error is 13%. At 1% noise level, the number of projections can be reduced to 8 while maintaining CT image and deformation errors of less than 4% and 13%, respectively. The method is sensitive to contrast mismatch between the simulated projections and the target projections when the soft-tissue contrast in the projections is low.
CONCLUSIONS: By using prior knowledge available in a FBCT image, the authors show that a CBCT image can be iteratively reconstructed from a comparatively small number of projection images, thus saving acquisition time and reducing imaging dose. This will enable more frequent daily imaging during radiation therapy. Because the process preserves the CT numbers of the FBCT image, the resulting 3D image intensities will be more accurate than a CBCT image reconstructed via conventional backprojection methods. Reconstruction errors are insensitive to noise at levels beyond what would typically be found in CBCT projection data, but are sensitive to contrast mismatch errors between the CBCT projection data and the DRRs.

Entities:  

Mesh:

Year:  2010        PMID: 21302778      PMCID: PMC2997812          DOI: 10.1118/1.3515460

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

Review 2.  Emergent technologies for 3-dimensional image-guided radiation delivery.

Authors:  David A Jaffray
Journal:  Semin Radiat Oncol       Date:  2005-07       Impact factor: 5.934

3.  Digital tomosynthesis with an on-board kilovoltage imaging device.

Authors:  Devon J Godfrey; Fang-Fang Yin; Mark Oldham; Sua Yoo; Christopher Willett
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-05-01       Impact factor: 7.038

Review 4.  Overview of image-guided radiation therapy.

Authors:  Lei Xing; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Tian-Fang Li; Gwe-Ya Kim; Gary Luxton; Albert Koong
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

5.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

Authors:  Martin J Murphy; James Balter; Stephen Balter; Jose A BenComo; Indra J Das; Steve B Jiang; C M Ma; Gustavo H Olivera; Raymond F Rodebaugh; Kenneth J Ruchala; Hiroki Shirato; Fang-Fang Yin
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

6.  Fast parametric elastic image registration.

Authors:  Jan Kybic; Michael Unser
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

7.  Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery.

Authors:  Michel Ghilezan; Di Yan; Jian Liang; David Jaffray; John Wong; Alvaro Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-12-01       Impact factor: 7.038

Review 8.  Image-guided radiotherapy: rationale, benefits, and limitations.

Authors:  Laura A Dawson; Michael B Sharpe
Journal:  Lancet Oncol       Date:  2006-10       Impact factor: 41.316

9.  Automatic image guidance for prostate IMRT using low dose CBCT.

Authors:  Marcin Wierzbicki; Bryan Schaly; Terry Peters; Rob Barnett
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

10.  Reduction in x-ray scatter and radiation dose for volume-of-interest (VOI) cone-beam breast CT--a phantom study.

Authors:  Chao-Jen Lai; Lingyun Chen; Huojun Zhang; Xinming Liu; Yuncheng Zhong; Youtao Shen; Tao Han; Shuaiping Ge; Ying Yi; Tianpeng Wang; Wei T Yang; Gary J Whitman; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-10-20       Impact factor: 3.609

View more
  10 in total

1.  4D Cone-beam CT reconstruction using a motion model based on principal component analysis.

Authors:  David Staub; Alen Docef; Robert S Brock; Constantin Vaman; Martin J Murphy
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Authors:  Hao Yan; Xin Zhen; Michael Folkerts; Yongbao Li; Tinsu Pan; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

3.  Preliminary clinical evaluation of a 4D-CBCT estimation technique using prior information and limited-angle projections.

Authors:  You Zhang; Fang-Fang Yin; Tinsu Pan; Irina Vergalasova; Lei Ren
Journal:  Radiother Oncol       Date:  2015-03-26       Impact factor: 6.280

4.  A digitally reconstructed radiograph algorithm calculated from first principles.

Authors:  David Staub; Martin J Murphy
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

Review 5.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

6.  A new CT reconstruction technique using adaptive deformation recovery and intensity correction (ADRIC).

Authors:  You Zhang; Jianhua Ma; Puneeth Iyengar; Yuncheng Zhong; Jing Wang
Journal:  Med Phys       Date:  2017-05-12       Impact factor: 4.071

7.  An unsupervised 2D-3D deformable registration network (2D3D-RegNet) for cone-beam CT estimation.

Authors:  You Zhang
Journal:  Phys Med Biol       Date:  2021-03-24       Impact factor: 4.174

8.  3D-2D Deformable Image Registration Using Feature-Based Nonuniform Meshes.

Authors:  Zichun Zhong; Xiaohu Guo; Yiqi Cai; Yin Yang; Jing Wang; Xun Jia; Weihua Mao
Journal:  Biomed Res Int       Date:  2016-02-25       Impact factor: 3.411

9.  Motion guided Spatiotemporal Sparsity for high quality 4D-CBCT reconstruction.

Authors:  Yang Liu; Xi Tao; Jianhua Ma; Zhaoying Bian; Dong Zeng; Qianjin Feng; Wufan Chen; Hua Zhang
Journal:  Sci Rep       Date:  2017-12-12       Impact factor: 4.379

10.  Evaluation and Clinical Application of a Commercially Available Iterative Reconstruction Algorithm for CBCT-Based IGRT.

Authors:  Weihua Mao; Chang Liu; Stephen J Gardner; Farzan Siddiqui; Karen C Snyder; Akila Kumarasiri; Bo Zhao; Joshua Kim; Ning Winston Wen; Benjamin Movsas; Indrin J Chetty
Journal:  Technol Cancer Res Treat       Date:  2019-01-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.