Literature DB >> 21300452

The effect of pro-qura case volume on post-implant prostate dosimetry.

Gregory S Merrick1, Jonathan H Lief, Peter Grimm, John Sylvester, Wayne M Butler, Zachariah A Allen.   

Abstract

PURPOSE: To evaluate the effect of prostate brachytherapy case volume on postimplant dosimetric quality in Pro-Qura proctored programs. METHODS AND MATERIALS: From August 1999 to December 2008, the computed tomography datasets for 6,600 prostate implants performed by 129 brachytherapists were submitted to Pro-Qura for dosimetric analysis. Brachytherapists were divided into three roughly equal-sized terciles based on total case volume. Postimplant computed tomography scans were obtained at a median of 30 days. Excellent target coverage was defined by a V100≥90% and D90≥100% minimum prescribed peripheral dose. To determine if the number of excellent implants improved with increasing case numbers, each brachytherapist's series of implants was bisected into early and late experience by a moveable critical point.
RESULTS: For the entire cohort, the mean V100 and D90 were 89.2% and 102.8%, respectively, with 47.7% of the implants scored as excellent. Brachytherapists in the highest-case tercile had a significantly greater fraction of excellent target coverage (57.9%) than did those in the two lower terciles (39.5% and 45.7%, p=0.015). Twenty-one (25.6%) of the 82 brachytherapists with sufficient case volume for dosimetric improvement analyses demonstrated quality improvement over time. Although there was no significant difference between prostate volume and seed strength, the number of seeds used was significantly greater in adequate implants.
CONCLUSIONS: The highest-volume brachytherapists were most likely to obtain excellent target coverage. We are encouraged that in general practice, nearly 48% of all implants were scored excellent. It is conceivable that with greater expert third-party involvement, an even greater percentage of cases with excellent target coverage will become reality.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21300452     DOI: 10.1016/j.ijrobp.2010.10.076

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Results from the Quality Research in Radiation Oncology (QRRO) survey: Evaluation of dosimetric outcomes for low-dose-rate prostate brachytherapy.

Authors:  Michael J Zelefsky; Gil'ad N Cohen; Walter R Bosch; Lisa Morikawa; Najma Khalid; Cheryl L Crozier; W Robert Lee; Anthony Zietman; Jean Owen; J Frank Wilson; Phillip M Devlin
Journal:  Brachytherapy       Date:  2012-07-21       Impact factor: 2.362

2.  Racial and socioeconomic disparities in the selection of prostate brachytherapy.

Authors:  David Schreiber; Shan-Chin Chen; Justin Rineer; Jeffrey Weiss; Marvin Rotman; David Schwartz
Journal:  J Contemp Brachytherapy       Date:  2013-09-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.