Literature DB >> 21300108

Unsuitability of exhaled breath condensate for the detection of herpesviruses DNA in the respiratory tract.

Cristina Costa1, Caterina Bucca, Massimiliano Bergallo, Paolo Solidoro, Giovanni Rolla, Rossana Cavallo.   

Abstract

Exhaled breath condensate is a non-invasive method for detecting a wide number of molecules as well as genomic DNA in the airways. No study investigated the detection of viral DNA in exhaled breath condensate, while only one study excluded its usefulness for detection of influenza virus RNA. In this study, the suitability of exhaled breath condensate for detecting herpesviruses infection or reactivation in the respiratory tract of lung transplant recipients was evaluated. Twenty-four matched samples (exhaled breath condensate, bronchoalveolar lavage, whole blood, transbronchial biopsy) were evaluated for the detection of human cytomegalovirus (HCMV), human herpesvirus (HHV-6 and -7), Epstein-Barr virus (EBV) DNA by real-time PCR. Eighteen bronchoalveolar lavages (75%), six whole blood samples (25%), and two transbronchial biopsies (8.3%) were positive for at least one herpesvirus. Only one exhaled breath condensate specimen was positive for HCMV DNA (and positive also in the bronchoalveolar lavage, with low viral load in both specimens); while no other patient, irrespective of the viral load in any specimen or the presence of clinical symptoms and signs, had a positive exhaled breath condensate. These findings seem to exclude the suitability of exhaled breath condensate for non-invasive detection of viral DNA in the respiratory tract of lung transplant recipients.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21300108     DOI: 10.1016/j.jviromet.2011.02.004

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  2 in total

1.  Exploring alternative biomaterials for diagnosis of pulmonary tuberculosis in HIV-negative patients by use of the GeneXpert MTB/RIF assay.

Authors:  Shubhada Shenai; Danielle Amisano; Katharina Ronacher; Magdalena Kriel; Padmapriya P Banada; Taeksun Song; Myungsun Lee; Joon Sung Joh; Jill Winter; Rich Thayer; Laura E Via; Soyeon Kim; Clifton E Barry; Gerhard Walzl; David Alland
Journal:  J Clin Microbiol       Date:  2013-10-09       Impact factor: 5.948

2.  Use of an innovative and non-invasive device for virologic sampling of cough aerosols in patients with community and hospital acquired pneumonia: a pilot study.

Authors:  Filippo Patrucco; Francesco Gavelli; Paolo Ravanini; Matteo Daverio; Giulia Statti; Luigi Mario Castello; Stefano Andreoni; Piero Emilio Balbo
Journal:  J Breath Res       Date:  2019-03-01       Impact factor: 3.262

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.