Literature DB >> 21300018

Analysis of glycated hemoglobin A1c by capillary electrophoresis and capillary isoelectric focusing.

Dušan Koval1, Václav Kašička, Hervé Cottet.   

Abstract

Two capillary electrophoretic methods were developed and evaluated for measurement of glycated hemoglobin A1c (HbA1c). First, a capillary electrophoresis analysis is performed with a sodium tetraborate buffer (pH 9.3) as background electrolyte in a neutrally coated capillary. HbA1c is separated from HbA0 due to specific interactions of borate anions with the cis-diol pattern in the saccharide moiety of glycohemoglobin. Second, a capillary isoelectric focusing method, which exploits a difference in pI values of HbA0 and HbA1c, is performed with Servalyt pH 6-8 or alternatively with Biolyte pH 6-8 carrier ampholytes spiked with a narrow pH cut of pH 7.2 prepared by preparative fractionation of Servalyt pH 4-9 carrier ampholytes. Both methods reflect recent developments in the methodology of capillary electrophoresis. They allow quantifying HbA1c in generic capillary electrophoresis analyzer with specificity that is consistent with previously reported electrophoretic assays in slab gels and capillaries.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21300018     DOI: 10.1016/j.ab.2011.01.048

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

Review 1.  A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin.

Authors:  Zhikun Zhan; Yang Li; Yuliang Zhao; Hongyu Zhang; Zhen Wang; Boya Fu; Wen Jung Li
Journal:  Biosensors (Basel)       Date:  2022-04-08

Review 2.  Current Status of HbA1c Biosensors.

Authors:  Hua Lin; Jun Yi
Journal:  Sensors (Basel)       Date:  2017-08-04       Impact factor: 3.576

Review 3.  Recent Progress in Electrochemical HbA1c Sensors: A Review.

Authors:  Baozhen Wang; Jun-Ichi Anzai
Journal:  Materials (Basel)       Date:  2015-03-17       Impact factor: 3.623

4.  Intact and middle-down CIEF of commercial therapeutic monoclonal antibody products under non-denaturing conditions.

Authors:  Johannes Schmailzl; Marcel W Vorage; Hanno Stutz
Journal:  Electrophoresis       Date:  2020-04-27       Impact factor: 3.535

5.  Label-free quantitation of glycated hemoglobin in single red blood cells by transient absorption microscopy and phasor analysis.

Authors:  Pu-Ting Dong; Haonan Lin; Kai-Chih Huang; Ji-Xin Cheng
Journal:  Sci Adv       Date:  2019-05-10       Impact factor: 14.136

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.