Literature DB >> 21299745

Alloantibodies to factor VIII in haemophilia.

A Zakarija1, S Harris, A W Rademaker, J Brewer, J Krudysz-Amblo, S Butenas, K G Mann, D Green.   

Abstract

Up to one-third of haemophilia A patients develop factor VIII (FVIII) alloantibodies (inhibitors). The Bethesda assay detects inhibitors but is relatively insensitive. Recently, a new fluorescence-based immunoassay (FLI) was developed for antibody detection. The aim of this study was to assess the prevalence of inhibitors as measured by FLI. Assays of FVIII, FVIII inhibitor by Bethesda assay with Nijmegen modification, and FVIII inhibitor by FLI were performed on adult patients with haemophilia A. Data were complete for 46 patients (median age 39), of whom 72% were severe, 7% moderate and 22% mild. The Bethesda assay was positive in only two patients (4%), while FLI was positive in 23 of 46 patients (50%), with values ranging from 0.4 to 33.7 nm (median 3.5 nm). FLI titres exceeded 7.0 nm in 19.5% of patients, all but one of whom had severe haemophilia. FLI antibody-positive patients were less likely to be HIV positive (30% vs. 70%, P = 0.02). The use of a prophylaxis regimen was associated with a lower incidence of antibody; only two of 23 patients with detectable antibody and none of those with antibody >7 nm were on a prophylaxis regimen, while nine of 23 patients without antibody were on prophylaxis, (P = 0.03). There was no difference in inhibitor presence in patients using recombinant versus plasma-derived factor. Antibodies detected by FLI are frequent in patients with haemophilia A, but are less common in those who are HIV positive or are receiving regular FVIII prophylaxis.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21299745     DOI: 10.1111/j.1365-2516.2010.02468.x

Source DB:  PubMed          Journal:  Haemophilia        ISSN: 1351-8216            Impact factor:   4.287


  8 in total

1.  Product-dependent anti-factor VIII antibodies.

Authors:  S Butenas; J Krudysz-Amblo; G E Rivard; K G Mann
Journal:  Haemophilia       Date:  2013-04-04       Impact factor: 4.287

2.  Evaluation of inhibitor antibody in hemophiliaA population.

Authors:  Hassan Mahmoodi Nesheli; Amereh Hadizadeh; Ali Bijani
Journal:  Caspian J Intern Med       Date:  2013

3.  Characterization of the anti-factor VIII immunoglobulin profile in patients with hemophilia A by use of a fluorescence-based immunoassay.

Authors:  B Boylan; A S Rice; A L Dunn; M D Tarantino; D B Brettler; J C Barrett; C H Miller
Journal:  J Thromb Haemost       Date:  2014-12-11       Impact factor: 5.824

4.  Factor VIII inhibitors in hemophilia A: rationale and latest evidence.

Authors:  Char Witmer; Guy Young
Journal:  Ther Adv Hematol       Date:  2013-02

5.  Comparison of clot-based, chromogenic and fluorescence assays for measurement of factor VIII inhibitors in the US Hemophilia Inhibitor Research Study.

Authors:  C H Miller; A S Rice; B Boylan; A D Shapiro; S R Lentz; B M Wicklund; F M Kelly; J M Soucie
Journal:  J Thromb Haemost       Date:  2013-07       Impact factor: 5.824

6.  Prevalence and Incidence of Non-neutralizing Antibodies in Congenital Hemophilia A- A Systematic Review and Meta-Analysis.

Authors:  A Abdi; M R Bordbar; S Hassan; F R Rosendaal; J G van der Bom; J Voorberg; K Fijnvandraat; S C Gouw
Journal:  Front Immunol       Date:  2020-05-07       Impact factor: 7.561

7.  Phenotypes of allo- and autoimmune antibody responses to FVIII characterized by surface plasmon resonance.

Authors:  Kenneth B Lewis; Richard J Hughes; Melinda S Epstein; Neil C Josephson; Christine L Kempton; Craig M Kessler; Nigel S Key; Tom E Howard; Rebecca Kruse-Jarres; Jeanne M Lusher; Christopher E Walsh; Raymond G Watts; Ruth A Ettinger; Kathleen P Pratt
Journal:  PLoS One       Date:  2013-05-08       Impact factor: 3.240

8.  Evaluation of anti-factor VIII antibody levels in patients with haemophilia A receiving immune tolerance induction therapy or bypassing agents.

Authors:  Brian Boylan; Glenn P Niemeyer; Bonnie Werner; Connie H Miller
Journal:  Haemophilia       Date:  2020-11-20       Impact factor: 4.263

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.