Literature DB >> 21298653

Impact of preprocedural high-sensitivity C-reactive protein levels on uncovered stent struts: an optical coherence tomography study after drug-eluting stent implantation.

Byeong-Keuk Kim1, Jung-Sun Kim, Changmyung Oh, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong.   

Abstract

BACKGROUND: There are no sufficient data to evaluate the relationship between high-sensitivity C-reactive protein (hs-CRP) and uncovered stent struts on optical coherence tomography (OCT) after drug-eluting stent (DES) implantation. HYPOTHESIS: We evaluated the relationship between the preprocedural level of hs-CRP and incomplete neointimal coverage of DES struts on OCT.
METHODS: This study was conducted using 124 eligible patients (132 lesions) treated with sirolimus-eluting stents (SES) or zotarolimus-eluting stents (ZES). The subjects were divided into 2 groups based on the preprocedural hs-CRP level: high-CRP (≥3 mg/L; 58 lesions) and normal-CRP (<3 mg/L, 74 lesions) groups. The percentage of uncovered struts, calculated as the ratio of uncovered struts to total struts in all OCT cross-sections, was compared between the 2 groups according to initial clinical presentation (stable angina [SA] vs acute coronary syndrome) and the type of implanted DES (SES vs ZES).
RESULTS: There was no significant correlation between hs-CRP and the percentage of uncovered struts on OCT in all enrolled lesions. In the SA subgroup, the percentage of uncovered struts was significantly higher in the high-CRP group than in the normal-CRP group (8.1 ± 11.6% vs 3.8 ± 7.9%, P = 0.018). There was significant correlation between hs-CRP level and the percentage of uncovered struts in SA patients with SES (r = 0.280, P = 0.039), but not ZES (r = - 0.063, P = 0.729).
CONCLUSIONS: Preprocedural hs-CRP level could affect incomplete neointimal coverage of struts after DES implantation depending on the initial clinical presentation and the type of implanted DES.
© 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21298653      PMCID: PMC6652423          DOI: 10.1002/clc.20856

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882