Literature DB >> 21297743

Failure of intrauterine contraceptives: a review.

J D Allingham.   

Abstract

Accidental pregnancies with intrauterine devices may in part be attributed to inappropriate patient selection, lack of insertion expertise by physicians, and downward migration of IUDs from initial placement position. Available research on these factors is reviewed and a clinical protocol using ultrasound is proposed to detect and correct malpositioned devices.

Entities:  

Year:  1979        PMID: 21297743      PMCID: PMC2383081     

Source DB:  PubMed          Journal:  Can Fam Physician        ISSN: 0008-350X            Impact factor:   3.275


  13 in total

1.  Factors affecting intrauterine contraceptive device performance. I. Endometrial cavity length.

Authors:  H M Hasson; G S Berger; D A Edelman
Journal:  Am J Obstet Gynecol       Date:  1976-12-15       Impact factor: 8.661

2.  Diagnostic ultrasound in the management of patients using intrauterine contraceptive devices.

Authors:  B K Wittmann; T T Chow
Journal:  Br J Obstet Gynaecol       Date:  1976-10

3.  Sonographic visualization of coexisting gestation sac and I.U.D. in the uterus and a consideration of a causative factor of accidental pregnancy.

Authors:  W S Tsai; H Y Chen; Y P Chen; P Y Wei
Journal:  Int J Fertil       Date:  1973

4.  The in situ IUD and pregnancy outcome.

Authors:  R M Shine; J F Thompson
Journal:  Am J Obstet Gynecol       Date:  1974-05-01       Impact factor: 8.661

5.  The anchoring mechanism of retention of the Copper T device.

Authors:  I Kamal; M Ghoneim; M Talaat; A Mallawani
Journal:  Fertil Steril       Date:  1973-03       Impact factor: 7.329

6.  Uterine length: a prognostic indicator for the successful use of the copper 7 intrauterine device.

Authors:  Y Gibor; L Deysach; C H Nissen
Journal:  J Reprod Med       Date:  1973-11       Impact factor: 0.142

7.  Studies on intrauterine contraceptive devices. IV. The position of IUD in the cavity of uterus and nidation of fertilized ova.

Authors:  M Sakurabayashi; T Mohri; T Ono; H Takabatake
Journal:  Acta Obstet Gynaecol Jpn       Date:  1969-10

8.  An overview of IUD research and implications for the future.

Authors:  J Zipper; D A Edelman; A Goldsmith
Journal:  Int J Gynaecol Obstet       Date:  1977       Impact factor: 3.561

9.  The size and shape of the uterine cavity determined by hysterography with an intrauterine contraceptive device as a marker.

Authors:  M S Burnhill; C H Birnberg
Journal:  Int J Fertil       Date:  1966 Apr-Jun

10.  Pregnancies in the presence of copper intra-uterine devices. Hysterosalpingographic studies.

Authors:  I Kamal; M Ghoneim; M Talaat; M Abdalla; M Eid; E Rawia
Journal:  Int J Gynaecol Obstet       Date:  1976       Impact factor: 3.561

View more