Literature DB >> 21297453

Influence of 8 and 24-h storage of whole blood at ambient temperature on prothrombin time, activated partial thromboplastin time, fibrinogen, thrombin time, antithrombin and D-dimer.

Bettina Kemkes-Matthes1, Ronald Fischer, Dirk Peetz.   

Abstract

This study evaluates the effect of whole blood storage on common coagulation parameters in order to confirm or revise acceptable storage limits as defined by current guidelines and diverse study reports. Aliquots were taken from the citrated whole blood of inpatients and outpatients (n = 147) within 4 h after blood withdrawal and after extended storage of whole blood for 8 and 24 h at ambient temperature. Aliquots were centrifuged and analyzed for prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen (Fbg), antithrombin (AT), thrombin time (TT) and D-dimer. For each parameter, samples from 33-56 patients were investigated covering a wide range of normal and pathological values. Samples from patients receiving heparin were excluded from analyses of APTT and TT. All assays were performed using reagents and an analyzer from Siemens Healthcare Diagnostics Products GmbH. The mean percentage change after 8 and 24-h storage was below 10% for all parameters. Considering the changes in individual samples, all parameters can be reliably tested after 8-h storage, since less than 15% of the samples demonstrated individual changes of above 10%. The acceptable storage time can be extended to 24 h for PT, TT and D-dimer. Clinically relevant changes were detected after 24-h storage for APTT: 41% of the investigated samples demonstrated changes of above 10%. After 24-h storage, changes for Fbg and AT values were more than 15% in five out of 49 and in three out of 45 samples, respectively. This sporadic increase of values is clinically acceptable except for borderline samples.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21297453     DOI: 10.1097/MBC.0b013e328343f8bf

Source DB:  PubMed          Journal:  Blood Coagul Fibrinolysis        ISSN: 0957-5235            Impact factor:   1.276


  3 in total

1.  Micro-mechanical blood clot testing using smartphones.

Authors:  Justin Chan; Kelly Michaelsen; Joanne K Estergreen; Daniel E Sabath; Shyamnath Gollakota
Journal:  Nat Commun       Date:  2022-02-11       Impact factor: 14.919

2.  Assessment of Stability of Prothrombin Time, International Normalized Ratio, and Activated Partial Thromboplastin Time Under Different Storage Conditions in Human Plasma.

Authors:  Parag Patil; Tushar Sehgal; Priyanka Goswami; Malvika Gaur; Maroof Khan; Shivam Pandey; Sudip K Datta
Journal:  Cureus       Date:  2022-01-15

3.  Effects of storage time and temperature on coagulation tests and factors in fresh plasma.

Authors:  Limin Feng; Ying Zhao; Hongcan Zhao; Zhexin Shao
Journal:  Sci Rep       Date:  2014-01-27       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.