| Literature DB >> 21297153 |
Anne Kristin M Fell1, Hilde Notø, Marit Skogstad, Karl-Christian Nordby, Wijnand Eduard, Martin Veel Svendsen, Reidun Ovstebø, Anne Marie Siebke Trøseid, Johny Kongerud.
Abstract
OBJECTIVES: To study possible effects of aerosol exposure on lung function, fractional exhaled nitric oxide (FeNO) and inflammatory markers in blood from Norwegian cement production workers across one work shift (0 to 8 h) and again 32 h after the non-exposed baseline registration.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21297153 PMCID: PMC3191466 DOI: 10.1136/oem.2010.057729
Source DB: PubMed Journal: Occup Environ Med ISSN: 1351-0711 Impact factor: 4.402
Figure 1Flowchart for the inclusion and exclusion of cement production workers. *Lung function testing. **Workers who did not wish to participate 32 h after baseline.
Population characteristics given as mean (SD), duration of exposure and smoking status of cement production workers
| n | 95 |
| Age, years | 41 (13) |
| Height, cm | 179 (7) |
| Body mass index | 28 (4) |
| Duration of cement aerosol exposure, years | 16 (13) |
| Smoking status (%) | |
| Never-smokers | 36 |
| Ex-smokers | 23 |
| Smokers | 41 |
Including current smokers (n=37) and ex-smokers who stopped less than 1 year before the examinations (n=2).
Exposure measurements by job category, and the values for workers using respirators compared to those without respirators
| n | Inhalable aerosol | Thoracic aerosol | Respirable aerosol | |||||||
| AM | GM | GSD | AM | GM | GSD | AM | GM | GSD | ||
| Job category | ||||||||||
| Production | 37 | 5.2 | 2.3 | 4.5 | 0.65 | 0.32 | 3.6 | 0.37 | 0.20 | 3.4 |
| Electrical maintenance | 9 | 5.5 | 2.7 | 3.6 | 0.59 | 0.37 | 2.7 | 0.24 | 0.19 | 2.2 |
| Mechanical maintenance | 27 | 7.7 | 3.5 | 4.0 | 1.2 | 0.59 | 3.2 | 0.73 | 0.33 | 3.5 |
| Laboratory | 3 | 0.91 | 0.65 | 3.2 | 0.20 | 0.14 | 3.3 | 0.11 | 0.10 | 2.0 |
| Other | 19 | 7.8 | 4.0 | 4.3 | 1.1 | 0.52 | 4.2 | 0.46 | 0.31 | 2.6 |
| Total | 95 | 6.3 | 2.8 | 4.3 | 0.88 | 0.42 | 3.6 | 0.47 | 0.24 | 3.2 |
| Plant 1 | 39 | 5.2 | 2.5 | 3.8 | 0.62 | 0.30 | 3.5 | 0.36 | 0.21 | 3.0 |
| Without respirator | 18 | 1.4 | 0.90 | 2.8 | 0.16 | 0.11 | 2.4 | 0.13 | 0.088 | 2.3 |
| With respirator | 21 | 8.4 | 6.2 | 2.2 | 1.1 | 0.73 | 2.1 | 0.56 | 0.46 | 1.9 |
| Plant 2 | 56 | 7.1 | 3.0 | 4.7 | 1.1 | 0.52 | 3.5 | 0.55 | 0.27 | 3.2 |
| Without respirator | 43 | 4.6 | 2.5 | 3.7 | 0.60 | 0.40 | 2.8 | 0.32 | 0.21 | 2.5 |
| With respirator | 13 | 15 | 5.6 | 8.0 | 2.5 | 1.3 | 4.4 | 1.3 | 0.58 | 4.8 |
Significantly different from plant 1, p=0.04.
Significantly different from the category above, p<0.05.
p<0.001.
AM, arithmetic mean; GM, geometric mean; GSD, geometric standard deviation.
Selected lung function variables pre- and post-shift (0 and 8 h) in cement production workers, in non-smoking workers and in those without doctor-diagnosed asthma or allergy
| Parameter | Pre-shift (n=91), mean (SD) | Post-shift (n=91), mean (SD) | Cross-shift change | ||
| All workers (n=91), mean (95% CI) | No allergy/asthma (n=70), mean (95% CI) | Non-smokers (n=56), mean (95% CI) | |||
| FVC (litres) | 5.02 (0.91) | 4.99 (0.97) | −0.032 (−0.066 to 0.0016) | −0.041 (−0.080 to 0.0023) | −0.050 (−0.086 to 0.015) |
| FEV1 (litres) | 3.92 (0.81) | 3.88 (0.81) | −0.037 (−0.072 to 0.0017) | −0.046 (−0.086 to 0.0063) | −0.042 (−0.075 to 0.009) |
| FEV6 (litres) | 4.98 (0.93) | 4.95 (0.97) | −0.034 (−0.070 to 0.0088) | −0.046 (−0.087 to 0.0049) | −0.053 (−0.090 to 0.017) |
| FEV1/FVC | 78.1 (7.39) | 78.0 (7.06) | −0.15 (−0.69 to 0.37) | −0.20 (−0.79 to 0.40) | −0.034 (−0.58 to 0.51) |
| PEF (l/s) | 9.68 (1.69) | 9.73 (1.82) | 0.056 (−0084 to 0.20) | 0.053 (−0.11 to 0.21) | −0.0064 (−0.19 to 0.18) |
| FEF25–75% (l/s) | 3.39 (1.31) | 3.22 (1.30) | −0.17 (−0.26 to 0.081) | −0.18 (−0.28 to 0.070) | −0.15 (−0.24 to 0.057) |
| DL | 10.7 (2.1) | 10.5 (2.0) | −0.17 (−0.32 to 0.023) | −0.052 (−0.11 to 0.23) | −0.25 (−0.46 to 0.04) |
| KCO (mmol/min/kPa/l) | 1.57 (0.26) | 1.55 (0.26) | −0.02 (−0.044 to 0.010) | −0.0041 (−0.027 to 0.019) | −0.026 (−0.056 to 0.0035) |
| VA (litres) | 6.85 (1.06) | 6.85 (1.10) | 0.0037 (−0.061 to 0.069) | 0.020 (−0.058 to 0.098) | −0.015 (−0.10 to 0.072) |
Significantly changed from before work shift, p<0.05.
p<0.001.
n=89.
DLCO, carbon dioxide diffusion capacity; FEF, forced mid-expiratory flow rate; FEV1, forced expiratory volume in 1 s; FVC, forced vital capacity; KCO, carbon monoxide transfer per unit effective alveolar volume; PEF, peak expiratory flow; VA, alveolar volume.
Blood parameters and FeNO levels pre-and post-shift (0 and 8 h) and at 32 h
| Parameter | n | 0 h, median (range) | n | 8 h, median (range) | n | 32 h, median (range) |
| FeNO (ppb) | 58 | 14 (0–96) | 58 | 14 (0–98) | 55 | 12 (0–82) |
| Leucocytes (109/l) | 86 | 7.4 (4.8–13.5) | 86 | 8.0 (4.8–13.6) | 83 | 7.2 (4.3–14.3) |
| CRP (ng/l) | 93 | 1.58 (0.26–16.38) | 93 | 1.53 (0.19–12.79) | 90 | 1.87 (0.27–18.94) |
| Fibrinogen (g/l) | 86 | 3.09 (1.68–5.13) | – | – | 86 | 3.11 (2.26–5.08) |
| D-dimer (ng/l) | 86 | 0.29 (0.22–1.04) | – | – | 86 | 0.29 (0.22–1.04) |
| IL-1β (ng/l) | 88 | 0.25 (0.09–7.00) | 88 | 0.23 (0.09–3.51) | 88 | 0.20 (0.09–3.51) |
| IL-6 (ng/l) | 88 | 3.15 (0.35–25.40) | 88 | 3.30 (0.32–13.33) | 88 | 2.80 (0.98–23.94) |
| IL-8 (ng/l) | 88 | 7.61 (3.57–63.23) | 88 | 6.82 (1.70–59.30) | 88 | 6.21 (1.63–65.10) |
| IL-10 (ng/l) | 88 | 1.12 (0.18–10.78) | 88 | 0.91 (0.09–6.45) | 88 | 0.97 (0.10–4.55) |
| TNF-α (ng/l) | 88 | 5.47 (0.00–39.50) | 88 | 6.17 (0.47–69.53) | 88 | 5.51 (1.26–53.48) |
Significantly different from previous time point, p<0.05.
p<0.001.
Significantly different from 0 h, p<0.05.
p<0.001.
CRP, C reactive protein; FeNO, fractional exhaled nitric oxide.