Literature DB >> 21296706

Aligning scan acquisition circles in optical coherence tomography images of the retinal nerve fibre layer.

Haogang Zhu1, David P Crabb, Patricio G Schlottmann, Gadi Wollstein, David F Garway-Heath.   

Abstract

Optical coherence tomography (OCT) is widely used in the assessment of retinal nerve fibre layer thickness (RNFLT) in glaucoma. Images are typically acquired with a circular scan around the optic nerve head. Accurate registration of OCT scans is essential for measurement reproducibility and longitudinal examination. This study developed and evaluated a special image registration algorithm to align the location of the OCT scan circles to the vessel features in the retina using probabilistic modelling that was optimised by an expectation-maximization algorithm. Evaluation of the method on 18 patients undergoing large number of scans indicated improved data acquisition and better reproducibility of measured RNFLT when scanning circles were closely matched. The proposed method enables clinicians to consider the RNFLT measurement and its scan circle location on the retina in tandem, reducing RNFLT measurement variability and assisting detection of real change of RNFLT in the longitudinal assessment of glaucoma.

Entities:  

Mesh:

Year:  2011        PMID: 21296706     DOI: 10.1109/TMI.2011.2109962

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  8 in total

1.  Rates of retinal nerve fibre layer thickness change in glaucoma patients and control subjects.

Authors:  N O'Leary; P H Artes; D M Hutchison; M T Nicolela; B C Chauhan
Journal:  Eye (Lond)       Date:  2012-10-19       Impact factor: 3.775

2.  An automated detection of glaucoma using histogram features.

Authors:  Karthikeyan Sakthivel; Rengarajan Narayanan
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

3.  Retinal nerve fibre layer thickness floor and corresponding functional loss in glaucoma.

Authors:  Jean-Claude Mwanza; Donald L Budenz; Joshua L Warren; Aaron D Webel; Courtney E Reynolds; Diego T Barbosa; Shan Lin
Journal:  Br J Ophthalmol       Date:  2014-12-09       Impact factor: 4.638

4.  Glaucoma Diagnosis and Monitoring Using Advanced Imaging Technologies.

Authors:  Mitra Sehi; Shawn M Iverson
Journal:  US Ophthalmic Rev       Date:  2013

5.  Novel analytical methods for stratus OCT: alignment of the scan circle.

Authors:  Iván Marín-Franch; William H Swanson; Brittany R Adams; Haogang Zhu; David P Crabb
Journal:  Optom Vis Sci       Date:  2012-12       Impact factor: 1.973

Review 6.  Factors Affecting Cirrus-HD OCT Optic Disc Scan Quality: A Review with Case Examples.

Authors:  Joshua S Hardin; Giovanni Taibbi; Seth C Nelson; Diana Chao; Gianmarco Vizzeri
Journal:  J Ophthalmol       Date:  2015-08-13       Impact factor: 1.909

7.  Optical coherence tomography, scanning laser polarimetry and confocal scanning laser ophthalmoscopy in retinal nerve fiber layer measurements of glaucoma patients.

Authors:  Farsad Fanihagh; Stephan Kremmer; Gerasimos Anastassiou; Maurice Schallenberg
Journal:  Open Ophthalmol J       Date:  2015-03-31

Review 8.  An evidence-based approach to the routine use of optical coherence tomography.

Authors:  Angelica Ly; Jack Phu; Paula Katalinic; Michael Kalloniatis
Journal:  Clin Exp Optom       Date:  2018-12-17       Impact factor: 2.742

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.