Literature DB >> 21296705

Perception-based visualization of manifold-valued medical images using distance-preserving dimensionality reduction.

Ghassan Hamarneh1, Chris McIntosh, Mark S Drew.   

Abstract

A method for visualizing manifold-valued medical image data is proposed. The method operates on images in which each pixel is assumed to be sampled from an underlying manifold. For example, each pixel may contain a high dimensional vector, such as the time activity curve (TAC) in a dynamic positron emission tomography (dPET) or a dynamic single photon emission computed tomography (dSPECT) image, or the positive semi-definite tensor in a diffusion tensor magnetic resonance image (DTMRI). A nonlinear mapping reduces the dimensionality of the pixel data to achieve two goals: distance preservation and embedding into a perceptual color space. We use multidimensional scaling distance-preserving mapping to render similar pixels (e.g., DT or TAC pixels) with perceptually similar colors. The 3D CIELAB perceptual color space is adopted as the range of the distance preserving mapping, with a final similarity transform mapping colors to a maximum gamut size. Similarity between pixels is either determined analytically as geodesics on the manifold of pixels or is approximated using manifold learning techniques. In particular, dissimilarity between DTMRI pixels is evaluated via a Log-Euclidean Riemannian metric respecting the manifold of the rank 3, second-order positive semi-definite DTs, whereas the dissimilarity between TACs is approximated via ISOMAP. We demonstrate our approach via artificial high-dimensional, manifold-valued data, as well as case studies of normal and pathological clinical brain and heart DTMRI, dPET, and dSPECT images. Our results demonstrate the effectiveness of our approach in capturing, in a perceptually meaningful way, important features in the data.

Mesh:

Year:  2011        PMID: 21296705     DOI: 10.1109/TMI.2011.2111422

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Comparative analysis of nonlinear dimensionality reduction techniques for breast MRI segmentation.

Authors:  Alireza Akhbardeh; Michael A Jacobs
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Representation of lesion similarity by use of multidimensional scaling for breast masses on mammograms.

Authors:  Chisako Muramatsu; Kohei Nishimura; Tokiko Endo; Mikinao Oiwa; Misaki Shiraiwa; Kunio Doi; Hiroshi Fujita
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

3.  Method for Adapting the Grayscale Standard Display Function to the Aging Eye.

Authors:  Giovanni Ramponi; Aldo Badano
Journal:  J Digit Imaging       Date:  2017-02       Impact factor: 4.056

4.  Spectral embedding based active contour (SEAC) for lesion segmentation on breast dynamic contrast enhanced magnetic resonance imaging.

Authors:  Shannon C Agner; Jun Xu; Anant Madabhushi
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.