Literature DB >> 21296548

A biomechanical evaluation of press-fit stem constructs for tumor endoprosthetic reconstruction of the distal femur.

Peter C Ferguson1, Rad Zdero, Emil H Schemitsch, Benjamin M Deheshi, Robert S Bell, Jay S Wunder.   

Abstract

This study was designed to assess the biomechanical parameters of the older Kotz Modular Femur Tibia Reconstruction (Stryker Inc, Mahwah, NJ) stem and the newer Restoration and the unfluted Global Modular Replacement System (Stryker Inc, Mahwah, NJ) uncemented stems for use with tumor endoprostheses as well as to assess the optimal reaming technique for insertion of these stems. Fresh-frozen adult femora or composite distal femora were implanted with the uncemented stems. Separate experiments were performed to compare reaming technique and bone resection level. All constructs were mechanically tested for axial compression, lateral bending, and torsional stiffness and torque to failure. Results showed that the biomechanical performance of all the stems were similar with respect to each parameter. Cylindrical reaming was associated with a significantly higher torque to failure than flexible reaming in the diaphysis (P = .006). Newer uncemented stems provide adequate initial biomechanical stability for implantation in the distal femur.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21296548     DOI: 10.1016/j.arth.2010.12.005

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Osteointegration in Compliant Self-Adjusting Compression Fixation Shown by Backscatter Electron Microscopy: A Case Report.

Authors:  Alexander B Christ; Elexis Baral; Timothy M Wright; John H Healey
Journal:  HSS J       Date:  2019-06-11

2.  Early follow-up of a custom non-fluted diaphyseal press-fit tumour prosthesis.

Authors:  Patrick W O'Donnell; Anthony M Griffin; William C Eward; Amir Sternheim; Jay S Wunder; Peter C Ferguson
Journal:  Int Orthop       Date:  2013-09-05       Impact factor: 3.075

3.  Short-term clinical outcomes of Kyocera Modular Limb Salvage System designed cementless stems for the endoprosthetic reconstruction of lower extremities: a Japanese Musculoskeletal Oncology Group multi-institutional study.

Authors:  Satoshi Tsukushi; Yoshihiro Nishida; Takeshi Hirose; Eiji Nakata; Rumi Nakagawa; Tomoki Nakamura; Jungo Imanishi; Akihito Nagano; Hironari Tamiya; Takafumi Ueda
Journal:  BMC Cancer       Date:  2022-07-16       Impact factor: 4.638

4.  Distal femoral replacement - Cemented or cementless? Current concepts and review of the literature.

Authors:  Alexander B Christ; Francis J Hornicek; Nicola Fabbri
Journal:  J Clin Orthop Trauma       Date:  2021-05-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.