Coil embolization of persistent false lumen after stent graft repair of type B aortic dissection.

Enrique María San Norberto1, Vicente Manuel Gutiérrez, James Taylor, Carlos Vaquero.   

Abstract

Patent false lumen after endovascular stent graft treatment of type B aortic dissection is a predictor for late death and retreatment. Between June 2008 and March 2010, five men with patent false lumen, due to a type B dissection previously treated with thoracic stent graft, underwent endovascular coiling treatment. Within a 30-day period, there were no deaths or major complications. The follow-up duration ranged from 1 to 22 months (mean 10.6 ± 8.5). Endovascular coiling of patent false lumen after endovascular stent graft treatment for type B aortic dissection avoided the risk of rupture or death due to secondary aneurysm formation.
Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21296540     DOI: 10.1016/j.jvs.2010.11.110

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  2 in total

1.  Scheduled re-entry coil embolization before entry coverage of thoracic endovascular stent grafting for aneurysmal chronic type B aortic dissection.

Authors:  Keijiro Katayama; Naomichi Uchida; Shinya Takahashi; Taijiro Sueda
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-07-20

2.  False lumen embolization as a rescue technique in the setting of acute and chronic dissecting aneurysms as adjunct to thoracic endovascular aortic repair.

Authors:  Stephanie Rakestraw; Anthony Feghali; Kevin Nguyen; Dawn Salvatore; Paul DiMuzio; Babak Abai
Journal:  J Vasc Surg Cases Innov Tech       Date:  2020-02-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.