Literature DB >> 21292757

Does home sleep testing impair continuous positive airway pressure adherence in patients with obstructive sleep apnea?

Christine F Lettieri1, Christopher J Lettieri2, Kevin Carter3.   

Abstract

BACKGROUND: The increasing recognition of obstructive sleep apnea (OSA) and demand for polysomnography has created a need for home sleep testing (HST) using unattended diagnostic and titration studies. Although these studies increase access to care and reduce cost, the limited interaction with sleep laboratories may negatively affect positive airway pressure (PAP) adherence. We sought to determine the difference in PAP use between HST and traditional in-laboratory studies.
METHODS: This observational cohort study included 210 patients with OSA classified into three equal groups. Following preestablished guidelines, group 1 underwent unattended, type III home diagnostic and unattended home auto-adjustable PAP (APAP) titrations; group 2 underwent in-laboratory, type I diagnostic and continuous PAP titration studies; group 3 underwent type I diagnostic and APAP titration studies. Group 1 was primarily managed and educated in a primary care clinic, whereas groups 2 and 3 received extensive education in an academic sleep medicine center. Objective measures of PAP use during the first 4 to 6 weeks of therapy were compared between groups.
RESULTS: Type of study and location of care did not affect PAP adherence. PAP was used for 70%, 73%, and 72% of nights in groups 1, 2, and 3, respectively (P = .94). Mean hours of nightly use (4.4 ± 2.0 h, 4.7 ± 1.5 h, and 4.6 ± 1.5 h; P = .98) was also similar. Regular use was observed in 54%, 51%, and 50% of subjects (P = .84). Discontinuation rates were similar between groups.
CONCLUSIONS: PAP usage did not differ between those undergoing HST vs in-laboratory studies. HST offers a more accessible and cost-effective alternative without compromising therapeutic adherence.

Entities:  

Mesh:

Year:  2011        PMID: 21292757     DOI: 10.1378/chest.10-1060

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  3 in total

Review 1.  Methodological strategies in using home sleep apnea testing in research and practice.

Authors:  Jennifer N Miller; Paula Schulz; Bunny Pozehl; Douglas Fiedler; Alissa Fial; Ann M Berger
Journal:  Sleep Breath       Date:  2017-11-14       Impact factor: 2.816

2.  CPAP setup by mail: we're not there yet.

Authors:  Karin G Johnson; Douglas C Johnson
Journal:  J Clin Sleep Med       Date:  2022-08-01       Impact factor: 4.324

Review 3.  Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis.

Authors:  Mohamed El Shayeb; Leigh-Ann Topfer; Tania Stafinski; Lawrence Pawluk; Devidas Menon
Journal:  CMAJ       Date:  2013-11-11       Impact factor: 8.262

  3 in total