Literature DB >> 21290603

Orthogonal array design for the optimization of ionic liquid-based dispersive liquid-liquid microextraction of benzophenone-type UV filters.

Lei Ye1, Juanjuan Liu, Xin Yang, Yan Peng, Li Xu.   

Abstract

In the present study, dispersive liquid-liquid microextraction (DLLME) using an ionic liquid (IL) as the extractant was successfully developed to extract four benzophenone-type UV filters from the different water matrices. Orthogonal array experimental design (OAD), based on five factors and four levels (L(16)(4(5))), was employed to optimize IL-dispersive liquid-liquid microextraction procedure. The five factors included pH of sample solution, the volume of IL and methanol addition, extraction time and the amount of salt added. The optimal extraction condition was as follows. Sample solution was at a pH of 2.63 in the presence of 60 mg/mL sodium chloride; 30 μL IL and 15 μL methanol were used as extractant and disperser solvent, respectively; extraction was achieved by vortexing for 4 min. Using high-performance liquid chromatography-UV analysis, the limits of detection of the target analytes ranged between 1.9 and 6.4 ng/mL. The linear ranges were between 10 or 20 ng/mL and 1000 ng/mL. This procedure afforded a convenient, fast and cost-saving operation with high extraction efficiency for the model analytes. Spiked waters from two rivers and one lake were examined by the developed method. For the swimming pool water, the standard addition method was employed to determine the actual concentrations of the UV filters.
Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21290603     DOI: 10.1002/jssc.201000552

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  3 in total

1.  Magnetic Nanoparticle-Based Dispersive Solid-Phase Microextraction of Three UV Blockers Prior to Their Determination by HPLC-DAD.

Authors:  Suad E Abughrin; Usama Alshana; Sezgin Bakirdere
Journal:  Int J Environ Res Public Health       Date:  2022-05-16       Impact factor: 4.614

2.  Evaluating the Joint Toxicity of Two Benzophenone-Type UV Filters on the Green Alga Chlamydomonas reinhardtii with Response Surface Methodology.

Authors:  Feijian Mao; Yiliang He; Karina Yew-Hoong Gin
Journal:  Toxics       Date:  2018-01-10

3.  Magnetic Polyamide Nanocomposites for the Microextraction of Benzophenones from Water Samples.

Authors:  Hoda Ghambari; Emilia M Reyes-Gallardo; Rafael Lucena; Mohammad Saraji; Soledad Cárdenas
Journal:  Molecules       Date:  2019-03-08       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.