In vitro dissolution and corrosion study of calcium phosphate coatings elaborated by pulsed electrodeposition current on Ti6Al4V substrate.

R Drevet1, F Velard, S Potiron, D Laurent-Maquin, H Benhayoune.   

Abstract

Calcium-deficient hydroxyapatite (Ca-def-HAP) coatings on titanium alloy (Ti6Al4V) substrates are elaborated by pulsed electrodeposition. In vitro dissolution/precipitation process is investigated by immersion of the coated substrate into Dulbecco's Modified Eagle Medium (DMEM) from 1 h to 28 days. Calcium and phosphorus concentrations evolution in the biological liquid are determined by Induced Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) for each immersion time. Physical and chemical characterizations of the coating are performed by scanning electron microscopy (SEM) associated to Energy Dispersive X-ray Spectroscopy (EDXS) for X-ray microanalysis. Surface modifications are investigated by an original method based on the three-dimensional reconstruction of SEM images (3D-SEM). Moreover, corrosion measurements are carried out by potentiodynamic polarization experiments. The results show that the precipitation rate of the Ca-def HAP coating is more pronounced in comparison with that of stoichiometric hydroxyapatite (HAP) used as reference. The precipitated bone-like apatite coating is thick, homogenous and exhibits an improved link to the substrate. Consequently, the corrosion behaviour of the elaborated prosthetic material is improved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21290169     DOI: 10.1007/s10856-011-4251-5

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  18 in total

1.  Hydroxyapatite dip coated and uncoated titanium poly-axial pedicle screws: an in vivo bovine model.

Authors:  Omer S Yildirim; Bunyamin Aksakal; Salih C Hanyaloglu; Fazli Erdogan; Ali Okur
Journal:  Spine (Phila Pa 1976)       Date:  2006-04-15       Impact factor: 3.468

2.  Electrochemical processes of nucleation and growth of hydroxyapatite on titanium supported by real-time electrochemical atomic force microscopy.

Authors:  Noam Eliaz; Moshe Eliyahu
Journal:  J Biomed Mater Res A       Date:  2007-03-01       Impact factor: 4.396

Review 3.  Calcium phosphate-based osteoinductive materials.

Authors:  Racquel Zapanta LeGeros
Journal:  Chem Rev       Date:  2008-11       Impact factor: 60.622

4.  Comparative in vivo evaluation of porous and dense duplex titanium and hydroxyapatite coating with high roughnesses in different implantation environments.

Authors:  V Borsari; M Fini; G Giavaresi; M Tschon; R Chiesa; L Chiusoli; A Salito; L Rimondini; R Giardino
Journal:  J Biomed Mater Res A       Date:  2009-05       Impact factor: 4.396

5.  In vivo bone response and mechanical evaluation of electrosprayed CaP nanoparticle coatings using the iliac crest of goats as an implantation model.

Authors:  Corinne Schouten; Gert J Meijer; Jeroen J J P van den Beucken; Sander C G Leeuwenburgh; Lise T de Jonge; Joop G C Wolke; Paul H M Spauwen; John A Jansen
Journal:  Acta Biomater       Date:  2009-11-26       Impact factor: 8.947

6.  An electrodeposition method of calcium phosphate coatings on titanium alloy.

Authors:  Marco Antonio Lopez-Heredia; P Weiss; P Layrolle
Journal:  J Mater Sci Mater Med       Date:  2007-02       Impact factor: 3.896

7.  Hydroxyapatite coating on Ti6Al4V alloy by a sol-gel method.

Authors:  Diangang Wang; Chuanzhong Chen; Ting He; Tingquan Lei
Journal:  J Mater Sci Mater Med       Date:  2007-12-12       Impact factor: 3.896

8.  Micrometer level structural and chemical evaluation of electrodeposited calcium phosphate coatings on TA6V substrate by STEM-EDXS.

Authors:  H Benhayoune; P Laquerriere; E Jallot; A Perchet; L Kilian; G Balossier; J L Bubendorff; G D Sockalingum
Journal:  J Mater Sci Mater Med       Date:  2002-11       Impact factor: 3.896

9.  Pulsed laser deposition of hydroxyapatite thin films on Ti-6Al-4V: effect of heat treatment on structure and properties.

Authors:  G P Dinda; J Shin; J Mazumder
Journal:  Acta Biomater       Date:  2009-01-31       Impact factor: 8.947

10.  Adherent octacalciumphosphate coating on titanium alloy using modulated electrochemical deposition method.

Authors:  Shujie Lin; Racquel Z LeGeros; John P LeGeros
Journal:  J Biomed Mater Res A       Date:  2003-09-15       Impact factor: 4.396

View more
  2 in total

1.  Monetite and brushite coated magnesium: in vivo and in vitro models for degradation analysis.

Authors:  Shaylin Shadanbaz; Jemimah Walker; Tim B F Woodfield; Mark P Staiger; George J Dias
Journal:  J Mater Sci Mater Med       Date:  2013-10-01       Impact factor: 3.896

Review 2.  Progress in Niobium Oxide-Containing Coatings for Biomedical Applications: A Critical Review.

Authors:  Mir Saman Safavi; F C Walsh; Livia Visai; Jafar Khalil-Allafi
Journal:  ACS Omega       Date:  2022-03-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.