Literature DB >> 21283996

Analysis of achilles tendon vascularity with second-generation contrast-enhanced ultrasound.

Eugenio Genovese1, Mario Ronga, Chiara Recaldini, Federico Fontana, Leonardo Callegari, Nicola Maffulli, Carlo Fugazzola.   

Abstract

PURPOSE: To compare morphological, power Doppler, and contrast-enhanced ultrasound (CEUS) features of the Achilles tendon between asymptomatic athletes and athletes who had undergone surgical repair of a previous rupture.
METHODS: Twenty-four athletes were divided in two groups (A and B). Group A included 14 patients with a median age of 32 years (range 27 to 47 years) who had undergone surgical repair for unilateral Achilles tendon rupture. Group B (control group) included 10 subjects with a median age of 34 years (range 27 to 40 years) with no previous or present history of tendinopathy. All patients were evaluated with ultrasound, power Doppler, and CEUS with second-generation contrast agent. We studied the uninjured Achilles tendon in athletes of group A and either the left or the right Achilles tendon of the athletes in group B.
RESULTS: CEUS showed a significantly greater ability to detect a greater number of vascular spots within the uninjured tendon of group A compared to group B (<0.05).
CONCLUSIONS: In athletes who had suffered a tear of an Achilles tendon, CEUS detected small vessels that were not identified by power Doppler ultrasound in the uninjured contralateral Achilles tendon. CEUS is useful to evaluate vascularity not detected by other imaging techniques. Vascularity in the uninjured tendon seems to be increased in patients who had a previous rupture.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21283996     DOI: 10.1002/jcu.20789

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  5 in total

1.  Neovascularization in Achilles tendinopathy: have we been chasing a red herring?

Authors:  Johannes L Tol; Filippo Spiezia; Nicola Maffulli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-14       Impact factor: 4.342

2.  Operative versus conservative treatment of acute Achilles tendon ruptures: preliminary results of clinical outcome, kinematic MRI and contrast-enhanced ultrasound.

Authors:  Juana Kosiol; Alexander Keiler; Alexander Loizides; Hannes Gruber; Benjamin Henninger; Andreas Bölderl; Leonhard Gruber
Journal:  Arch Orthop Trauma Surg       Date:  2022-05-14       Impact factor: 3.067

Review 3.  Ultrasound in sports medicine: relevance of emerging techniques to clinical care of athletes.

Authors:  Eugene Sun Yim; Gianmichael Corrado
Journal:  Sports Med       Date:  2012-08-01       Impact factor: 11.928

4.  Doppler Flow Response Following Running Exercise Differs Between Healthy and Tendinopathic Achilles Tendons.

Authors:  Lucie Risch; Frank Mayer; Michael Cassel
Journal:  Front Physiol       Date:  2021-03-23       Impact factor: 4.566

5.  In Achilles tendinopathy, the neovascularization, detected by contrast-enhanced ultrasound (CEUS), is abundant but not related to symptoms.

Authors:  Armanda De Marchi; Simona Pozza; Enzo Cenna; Franco Cavallo; Giorgia Gays; Luca Simbula; Paola De Petro; Alessandro Massè; Giuseppe Massazza
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-27       Impact factor: 4.342

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.