Literature DB >> 21281196

Ultrasonographic characterization of the liver, caudal vena cava, portal vein, and gallbladder in goats.

Ueli Braun1, Kathrin Steininger.   

Abstract

OBJECTIVE: To characterize the localization, visible extent (ie, measurement of selected dimensions), and appearance of the liver, caudal vena cava, portal vein, and gallbladder during ultrasonography in healthy goats. ANIMALS: 27 female Saanen goats. PROCEDURES: A 5.0-MHz linear transducer was used to ultrasonographically examine the localization, visible extent of various dimensions, and appearance of the liver, caudal vena cava, portal vein, and gallbladder from the right side of each goat.
RESULTS: Images of the liver were obtained in all goats. The dorsal margin of the liver extended in a cranioventral to caudodorsal direction parallel to the caudal margin of the lungs. The greatest visible extent of the liver was evident at the seventh and eighth intercostal spaces (mean value, 15.9 cm), and width was evident at the 10th intercostal space (mean value, 5.2 cm). The caudal vena cava had a triangular shape on cross section; the maximum width in cross section, circumference, and surface area ranged from 1.2 to 1.8 cm, 4.8 to 5.2 cm, and 0.8 to 1.1 cm², respectively. The portal vein was round on cross section (diameter, 0.8 to 1.7 cm) with stellate ramifications into the liver parenchyma. The gallbladder was pear-shaped and variable in size; it extended beyond the ventral margin of the liver to a variable degree depending on the amount of bile. CONCLUSIONS AND CLINICAL RELEVANCE: Results provided information regarding the ultrasonographic appearance of the liver, caudal vena cava, portal vein, and gallbladder in healthy goats; these data may be useful during examination of goats with suspected liver disease.

Entities:  

Mesh:

Year:  2011        PMID: 21281196     DOI: 10.2460/ajvr.72.2.219

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  3 in total

1.  Transabdominal ultrasonographic findings in goats with paratuberculosis.

Authors:  Mohamed Tharwat; Fahd Al-Sobayil; Mahmoud Hashad; Sébastien Buczinski
Journal:  Can Vet J       Date:  2012-10       Impact factor: 1.008

2.  Ultrasonography of the liver and kidneys of healthy camels (Camelus dromedarius).

Authors:  Mohamed Tharwat; Fahd Al-Sobayil; Ahmed Ali; Sébastien Buczinski
Journal:  Can Vet J       Date:  2012-12       Impact factor: 1.008

3.  Ultrasonography of the spleen, liver, gallbladder, caudal vena cava and portal vein in healthy calves from birth to 104 days of age.

Authors:  Ueli Braun; Sonka Krüger
Journal:  Acta Vet Scand       Date:  2013-09-16       Impact factor: 1.695

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.