Literature DB >> 21280875

Wall shear stresses remain elevated in mature arteriovenous fistulas: a case study.

G T Carroll1, T M McGloughlin, P E Burke, M Egan, F Wallis, M T Walsh.   

Abstract

Maintaining vascular access (VA) patency continues to be the greatest challenge for dialysis patients. VA dysfunction, primarily due to venous neointimal hyperplasia development and stenotic lesion formation, is mainly attributed to complex hemodynamics within the arteriovenous fistula (AVF). The effect of VA creation and the subsequent geometrical remodeling on the hemodynamics and shear forces within a mature patient-specific AVF is investigated. A 3D reconstructed geometry of a healthy vein and a fully mature patient-specific AVF was developed from a series of 2D magnetic resonance image scans. A previously validated thresholding technique for region segmentation and lumen cross section contour creation was conducted in MIMICS 10.01, allowing for the creation of a 3D reconstructed geometry. The healthy vein and AVF computational models were built, subdivided, and meshed in GAMBIT 2.3. The computational fluid dynamic (CFD) code FLUENT 6.3.2 (Fluent Inc., Lebanon, NH) was employed as the finite volume solver to determine the hemodynamics and shear forces within the healthy vein and patient-specific AVF. Geometrical alterations were evaluated and a CFD analysis was conducted. Substantial geometrical remodeling was observed, following VA creation with an increase in cross-sectional area, out of plane curvature (maximum angle of curvature in AVF=30 deg), and angle of blood flow entry. The mean flow velocity entering the vein of the AVF is dramatically increased. These factors result in complex three-dimensional hemodynamics within VA junction (VAJ) and efferent vein of the AVF. Complex flow patterns were observed and the maximum and mean wall shear stress (WSS) magnitudes are significantly elevated. Flow reversal was found within the VAJ and efferent vein. Extensive geometrical remodeling during AVF maturation does not restore physiological hemodynamics to the VAJ and venous conduit of the AVF, and high WSS and WSS gradients, and flow reversal persist. It is theorized that the vessel remodelling and the continued non-physiological hemodynamics within the AVF compound to result in stenotic lesion development.

Entities:  

Mesh:

Year:  2011        PMID: 21280875     DOI: 10.1115/1.4003310

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  11 in total

Review 1.  Novel paradigms for dialysis vascular access: upstream hemodynamics and vascular remodeling in dialysis access stenosis.

Authors:  Andrea Remuzzi; Bogdan Ene-Iordache
Journal:  Clin J Am Soc Nephrol       Date:  2013-08-29       Impact factor: 8.237

2.  Spiral Laminar Flow is Associated with a Reduction in Disturbed Shear in Patient-Specific Models of an Arteriovenous Fistula.

Authors:  Connor V Cunnane; J Graeme Houston; Daniel T Moran; Stephen P Broderick; Rose A Ross; Michael T Walsh
Journal:  Cardiovasc Eng Technol       Date:  2022-09-23       Impact factor: 2.305

3.  Incomplete restoration of homeostatic shear stress within arteriovenous fistulae.

Authors:  Patrick M McGah; Daniel F Leotta; Kirk W Beach; R Eugene Zierler; Alberto Aliseda
Journal:  J Biomech Eng       Date:  2013-01       Impact factor: 2.097

4.  Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula.

Authors:  Patrick M McGah; Daniel F Leotta; Kirk W Beach; Alberto Aliseda
Journal:  Biomech Model Mechanobiol       Date:  2013-09-15

5.  Hemodynamics in the cephalic arch of a brachiocephalic fistula.

Authors:  M Boghosian; K Cassel; M Hammes; B Funaki; S Kim; X Qian; X Wang; P Dhar; J Hines
Journal:  Med Eng Phys       Date:  2014-03-30       Impact factor: 2.242

6.  Vascular remodeling in autogenous arterio-venous fistulas by MRI and CFD.

Authors:  Monica Sigovan; Vitaliy Rayz; Warren Gasper; Hugh F Alley; Christopher D Owens; David Saloner
Journal:  Ann Biomed Eng       Date:  2012-11-27       Impact factor: 3.934

Review 7.  The Role of Shear Stress in Arteriovenous Fistula Maturation and Failure: A Systematic Review.

Authors:  Leonard D Browne; Khalid Bashar; Philip Griffin; Eamon G Kavanagh; Stewart R Walsh; Michael T Walsh
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

8.  Experimental Assessment of Two Non-Contrast MRI Sequences Used for Computational Fluid Dynamics: Investigation of Consistency Between Techniques.

Authors:  C J MacDonald; R Hellmuth; L Priba; E Murphy; S Gandy; S Matthew; R Ross; J G Houston
Journal:  Cardiovasc Eng Technol       Date:  2020-07-01       Impact factor: 2.495

9.  Randomized pilot study to compare metal needles versus plastic cannulae in the development of complications in hemodialysis access.

Authors:  Rosa M Marticorena; Niki Dacouris; Sandra M Donnelly
Journal:  J Vasc Access       Date:  2018-02-28       Impact factor: 2.283

10.  True Brachial Artery Aneurysm in Patients with Previous Arterio-Venous Fistula Ligation and Immunosuppressant Therapy for Renal Transplantation: Case Report and Literature Review.

Authors:  Sorin Barac; Andreea Luciana Rata; Alexandra Ioana Popescu; Roxana Ramona Onofrei; Sorin Dan Chiriac
Journal:  Healthcare (Basel)       Date:  2022-03-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.