Literature DB >> 21279604

Amide proton transfer imaging of the human brain.

Jinyuan Zhou1.   

Abstract

Amide proton transfer (APT) imaging is a new MRI technique that detects endogenous mobile proteins and peptides in tissue via saturation of the amide protons in the peptide bonds. Initial studies have shown promise in detecting tumor and stroke, but this technique was hampered by magnetic field inhomogeneity and a low signal-to-noise ratio. Several important prerequisites for performing APT imaging experiments include designing an effective APT imaging pulse sequence based on the hardware capability, optimizing the experimental protocol for the best clinical imaging quality, and developing data-processing approaches for effective image assessment. In this chapter, technical issues, such as pulse sequence design and optimization, magnetic field inhomogeneity correction, specific absorption rate minimization, and scan duration, are addressed.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21279604      PMCID: PMC3547598          DOI: 10.1007/978-1-61737-992-5_10

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  15 in total

1.  Magnetization transfer in MRI: a review.

Authors:  R M Henkelman; G J Stanisz; S J Graham
Journal:  NMR Biomed       Date:  2001-04       Impact factor: 4.044

2.  A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST).

Authors:  K M Ward; A H Aletras; R S Balaban
Journal:  J Magn Reson       Date:  2000-03       Impact factor: 2.229

3.  Sensitive NMR detection of cationic-polymer-based gene delivery systems using saturation transfer via proton exchange.

Authors:  N Goffeney; J W Bulte; J Duyn; L H Bryant; P C van Zijl
Journal:  J Am Chem Soc       Date:  2001-09-05       Impact factor: 15.419

4.  Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI.

Authors:  Jinyuan Zhou; Jean-Francois Payen; David A Wilson; Richard J Traystman; Peter C M van Zijl
Journal:  Nat Med       Date:  2003-07-20       Impact factor: 53.440

Review 5.  The dynamics of water-protein interactions.

Authors:  R G Bryant
Journal:  Annu Rev Biophys Biomol Struct       Date:  1996

6.  Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-L-lysine and a starburst dendrimer.

Authors:  Michael T McMahon; Assaf A Gilad; Jinyuan Zhou; Phillip Z Sun; Jeff W M Bulte; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2006-04       Impact factor: 4.668

7.  Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments.

Authors:  Mina Kim; Joseph Gillen; Bennett A Landman; Jinyuan Zhou; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

8.  Magnetic resonance image-guided proteomics of human glioblastoma multiforme.

Authors:  Susan K Hobbs; Gongyi Shi; Ron Homer; Griff Harsh; Scott W Atlas; Mark D Bednarski
Journal:  J Magn Reson Imaging       Date:  2003-11       Impact factor: 4.813

9.  Metabolic profiles of human brain tumors using quantitative in vivo 1H magnetic resonance spectroscopy.

Authors:  F A Howe; S J Barton; S A Cudlip; M Stubbs; D E Saunders; M Murphy; P Wilkins; K S Opstad; V L Doyle; M A McLean; B A Bell; J R Griffiths
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

10.  Amide proton transfer (APT) contrast for imaging of brain tumors.

Authors:  Jinyuan Zhou; Bachchu Lal; David A Wilson; John Laterra; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

View more
  15 in total

1.  Defining an Acidosis-Based Ischemic Penumbra from pH-Weighted MRI.

Authors:  Jinyuan Zhou; Peter C M van Zijl
Journal:  Transl Stroke Res       Date:  2011-10-28       Impact factor: 6.829

2.  CEST signal at 2ppm (CEST@2ppm) from Z-spectral fitting correlates with creatine distribution in brain tumor.

Authors:  Kejia Cai; Anup Singh; Harish Poptani; Weiguo Li; Shaolin Yang; Yang Lu; Hari Hariharan; Xiaohong J Zhou; Ravinder Reddy
Journal:  NMR Biomed       Date:  2014-10-08       Impact factor: 4.044

3.  Creatine CEST MRI for Differentiating Gliomas with Different Degrees of Aggressiveness.

Authors:  Kejia Cai; Rong-Wen Tain; Xiaohong Joe Zhou; Frederick C Damen; Alessandro M Scotti; Hari Hariharan; Harish Poptani; Ravinder Reddy
Journal:  Mol Imaging Biol       Date:  2017-04       Impact factor: 3.488

4.  Added value of amide proton transfer imaging to conventional and perfusion MR imaging for evaluating the treatment response of newly diagnosed glioblastoma.

Authors:  Kye Jin Park; Ho Sung Kim; Ji Eun Park; Woo Hyun Shim; Sang Joon Kim; Seth A Smith
Journal:  Eur Radiol       Date:  2016-02-16       Impact factor: 5.315

5.  Mapping murine diabetic kidney disease using chemical exchange saturation transfer MRI.

Authors:  Feng Wang; David Kopylov; Zhongliang Zu; Keiko Takahashi; Suwan Wang; C Chad Quarles; John C Gore; Raymond C Harris; Takamune Takahashi
Journal:  Magn Reson Med       Date:  2015-11-26       Impact factor: 4.668

6.  Liver MRI with amide proton transfer imaging: feasibility and accuracy for the characterization of focal liver lesions.

Authors:  Nieun Seo; Ha-Kyu Jeong; Jin-Young Choi; Mi-Suk Park; Myeong-Jin Kim; Yong Eun Chung
Journal:  Eur Radiol       Date:  2020-08-12       Impact factor: 5.315

7.  Amide proton transfer imaging for differentiation of tuberculomas from high-grade gliomas: Preliminary experience.

Authors:  Karthik Kulanthaivelu; Shumyla Jabeen; Jitender Saini; Sanita Raju; Atchayaram Nalini; Nishanth Sadashiva; Shashank Hegde; Narayana Krishna Rolla; Indrajit Saha; Netravathi M; Seena Vengalil; Saikrishna Swaroop; Shilpa Rao
Journal:  Neuroradiol J       Date:  2021-04-07

8.  The use of variable delay multipulse chemical exchange saturation transfer for separately assessing different CEST pools in the human brain at 7T.

Authors:  Bárbara Schmitz-Abecassis; Elena Vinogradov; Jannie P Wijnen; Thijs van Harten; Evita C Wiegers; Hans Hoogduin; Matthias J P van Osch; Ece Ercan
Journal:  Magn Reson Med       Date:  2021-09-14       Impact factor: 3.737

9.  Noninvasive measurements of glycogen in perfused mouse livers using chemical exchange saturation transfer NMR and comparison to (13)C NMR spectroscopy.

Authors:  Corin O Miller; Jin Cao; Eduard Y Chekmenev; Bruce M Damon; Alan D Cherrington; John C Gore
Journal:  Anal Chem       Date:  2015-05-22       Impact factor: 6.986

Review 10.  Transformational Role of Medical Imaging in (Radiation) Oncology.

Authors:  Catherine Coolens; Matt N Gwilliam; Paula Alcaide-Leon; Isabella Maria de Freitas Faria; Fabio Ynoe de Moraes
Journal:  Cancers (Basel)       Date:  2021-05-23       Impact factor: 6.639

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.