Literature DB >> 21277304

Development and evaluation of a Luminex multiplex serology assay to detect antibodies to bovine herpes virus 1, parainfluenza 3 virus, bovine viral diarrhoea virus, and bovine respiratory syncytial virus, with comparison to existing ELISA detection methods.

Steve Anderson1, Phil Wakeley, Guy Wibberley, Kath Webster, Jason Sawyer.   

Abstract

Detection of circulating antibodies to bovine herpes virus 1 (BHV-1), parainfluenza 3 virus (PI3V), bovine viral diarrhoea virus (BVDV) and bovine respiratory syncytial virus (BRSV) using ELISA is widely used for veterinary diagnostics and surveillance. In this paper, the potential of a multiplex serology test based on Luminex technology, where all antibodies are simultaneously detected in a single assay was investigated. The performance of "in-house" separate ELISAs which use relatively crude lysates of cultured virus as capture antigens, was compared to the multiplex assay where the same antigens were covalently bound to the fluorescent beads used in the Luminex platform. A panel of field serum samples was tested by the multiplex assay in parallel with the separate routine ELISAs to provide a comparison between tests. The BHV-1 and PI3V components of the multiplex test showed similar sensitivities and specificities to the separate "in-house" ELISAs. The performance of the BVDV and BRSV components was less successful and was attributed to relatively low signal strength for these antigens, leading to higher assay variability and a reduced ability to distinguish positive and negative samples compared to the "in-house" ELISAs. The results illustrated that antigens commonly used successfully in ELISAs cannot always be transferred for use in alternative assay systems. The use of recombinant BVDV E2 protein was investigated and was shown to lead to an appreciable increase in signal strength compared to the use of crude BVDV antigen in the Luminex system. Crown
Copyright © 2011. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21277304     DOI: 10.1016/j.jim.2011.01.010

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  12 in total

1.  A duplex recombinant viral nucleoprotein microbead immunoassay for simultaneous detection of seroresponses to human respiratory syncytial virus and metapneumovirus infections.

Authors:  Yange Zhang; W Abdullah Brooks; Doli Goswami; Mustafizur Rahman; Stephen P Luby; Dean D Erdman
Journal:  J Virol Methods       Date:  2014-05-23       Impact factor: 2.014

2.  Simultaneous detection of seven enteric viruses associated with acute gastroenteritis by a multiplexed Luminex-based assay.

Authors:  Yan Liu; Zi-qian Xu; Qing Zhang; Miao Jin; Jie-mei Yu; Jin-song Li; Na Liu; Shu-xian Cui; Xiang-yu Kong; Hong Wang; Hui-ying Li; Wei-xia Cheng; Xue-jun Ma; Zhao-jun Duan
Journal:  J Clin Microbiol       Date:  2012-04-18       Impact factor: 5.948

3.  Development of whole-virus multiplex luminex-based serological assays for diagnosis of infections with kaposi's sarcoma-associated herpesvirus/human herpesvirus 8 homologs in macaques.

Authors:  Jonathan T Ryan; Timothy M Rose
Journal:  Clin Vaccine Immunol       Date:  2013-01-23

4.  Validation of a microsphere immunoassay for serological leptospirosis diagnosis in human serum by comparison to the current gold standard.

Authors:  Sarah J Wynwood; Mary-Anne A Burns; Glenn C Graham; Steven L Weier; David B McKay; Scott B Craig
Journal:  PLoS Negl Trop Dis       Date:  2015-03-25

Review 5.  Luminex and other multiplex high throughput technologies for the identification of, and host response to, environmental triggers of type 1 diabetes.

Authors:  Sharad Purohit; Ashok Sharma; Jin-Xiong She
Journal:  Biomed Res Int       Date:  2015-03-25       Impact factor: 3.411

6.  Oral antigen exposure in newborn piglets circumvents induction of oral tolerance in response to intraperitoneal vaccination in later life.

Authors:  J Alex Pasternak; Siew Hon Ng; Rachelle M Buchanan; Sonja Mertins; George K Mutwiri; Volker Gerdts; Heather L Wilson
Journal:  BMC Vet Res       Date:  2015-03-07       Impact factor: 2.741

7.  A multiplex liquid-chip assay based on Luminex xMAP technology for simultaneous detection of six common respiratory viruses.

Authors:  Yong Yan; Jian-Yong Luo; Yin Chen; Heng-Hui Wang; Guo-Ying Zhu; Pei-Yan He; Jin-Lei Guo; Yong-Liang Lei; Zhong-Wen Chen
Journal:  Oncotarget       Date:  2017-06-17

8.  Bead-Based Multiplex Assay for the Simultaneous Detection of Antibodies to African Swine Fever Virus and Classical Swine Fever Virus.

Authors:  Cristina Aira; Tamara Ruiz; Linda Dixon; Sandra Blome; Paloma Rueda; Patricia Sastre
Journal:  Front Vet Sci       Date:  2019-09-13

9.  Evaluation of envelope glycoprotein E(rns) of an atypical bovine pestivirus as antigen in a microsphere immunoassay for the detection of antibodies against bovine viral diarrhea virus 1 and atypical bovine pestivirus.

Authors:  Balaje Vijayaraghavan; Hongyan Xia; Rajiv Harimoorthy; Lihong Liu; Sándor Belák
Journal:  J Virol Methods       Date:  2012-07-02       Impact factor: 2.014

10.  Paper-Based Antibody Detection Devices Using Bioluminescent BRET-Switching Sensor Proteins.

Authors:  Keisuke Tenda; Benice van Gerven; Remco Arts; Yuki Hiruta; Maarten Merkx; Daniel Citterio
Journal:  Angew Chem Int Ed Engl       Date:  2018-09-19       Impact factor: 15.336

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.