Literature DB >> 21277220

Midterm outcome after aortic root replacement with stentless porcine bioprostheses.

Ina C Ennker1, Alexander Albert, Fatmir Dalladaku, Ulrich Rosendahl, Juergen Ennker, Ines Florath.   

Abstract

OBJECTIVE: Midterm clinical outcome was evaluated after aortic root replacement with Freestyle® stentless aortic root bioprostheses.
METHODS: Between April 1996 and December 2007, 301 patients underwent aortic valve replacement with stentless Medtronic Freestyle® bioprostheses in full-root technique at a single center. Concomitant coronary artery bypass grafting (CABG) was required in 96 patients (32%). In 94 patients (31%), the ascending aorta was replaced. The mean age was 71.6 ± 9.1 (range: 36-89) years. Follow-up was closed in October 2008, 99% complete and encompassed 916 patient-years.
RESULTS: Overall mortality within 30 days was 5%. A total of 62 patients died during the follow-up period. Overall survival at 5 and 9 years was 74 ± 4% and 53 ± 6%, respectively. Re-operations were required in three patients: in one patient due to structural valve deterioration, and in two patients due to prosthetic valve endocarditis. Non-structural dysfunctions were not observed. In eight patients, prosthetic valve endocarditis occurred, in most of them (N = 6) during the first year after surgery. Rate of freedom from re-operation, structural valve deterioration, prosthetic valve endocarditis, thrombo-embolic and major bleeding events at 9 years was 94 ± 6%, 94 ± 6%, 94 ± 3%, 87 ± 5%, and 95 ± 2%, respectively. The linearized rates of late adverse events in percent per patient-year were 0.35, 0.12, 0.83, 1.7, and 0.7, respectively, for re-operation, structural valve deterioration, prosthetic valve endocarditis, thrombo-embolic and major bleeding events. A little less than a quarter (22%) of the patients required anticoagulation therapy.
CONCLUSIONS: Aortic root replacement with the stentless Freestyle® bioprosthesis provided a respectable short-term mortality, optimal valve durability and acceptable rates of valve-related complications within 9 years.
Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21277220     DOI: 10.1016/j.ejcts.2010.12.010

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  4 in total

1.  Influence of Age on Longevity of a Stentless Aortic Valve.

Authors:  Bo Yang; Aroosa Malik; Linda Farhat; Alexander Makkinejad; Elizabeth L Norton; Mohamed-Ali Sareini; Emma St Pierre; Xiaoting Wu; Jonathan Haft; Matthew Romano; Steven F Bolling; Himanshu J Patel; G Michael Deeb
Journal:  Ann Thorac Surg       Date:  2019-12-23       Impact factor: 4.330

2.  Cardiac energetics analysis after aortic valve replacement with 16-mm ATS mechanical valve.

Authors:  Tomoki Ushijima; Yoshihisa Tanoue; Takayuki Uchida; Sho Matsuyama; Takashi Matsumoto; Ryuji Tominaga
Journal:  J Artif Organs       Date:  2014-05-25       Impact factor: 1.731

3.  Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots.

Authors:  Reza Tavakoli; Peiman Jamshidi; Max Gassmann
Journal:  J Vis Exp       Date:  2017-05-21       Impact factor: 1.355

4.  Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves.

Authors:  Reza Tavakoli; Christoph Auf der Maur; Xavier Mueller; Reinhard Schläpfer; Peiman Jamshidi; François Daubeuf; Nelly Frossard
Journal:  J Cardiothorac Surg       Date:  2015-02-03       Impact factor: 1.637

  4 in total