Literature DB >> 21277053

Biomechanical properties of the triceps surae muscle-tendon unit in young and postmenopausal women.

Aurélio Faria1, Ronaldo Gabriel, João Abrantes, Rui Brás, Helena Moreira.   

Abstract

BACKGROUND: Insufficient and excessive stiffness may increase the risk of soft tissue and bone injuries, respectively, while the resonance frequency seems to be related with energy expenditure and stiffness. With aging and menopause muscle weakness, physical fragility and mobility limitations are also expected. Therefore this study addresses the differences of biomechanical properties of the triceps surae muscle-tendon unit between young and postmenopausal women.
METHODS: 39 young and 37 postmenopausal women participated. The biomechanical properties of the triceps surae muscle-tendon unit were assessed in vivo using a free oscillation technique involving 30% of the maximal voluntary isometric contraction load.
FINDINGS: The postmenopausal women in this study show significant higher values in the damped natural frequency of oscillation (young 3.84Hz vs. postmenopausal 4.68Hz, P<0.001), muscle-tendon unit stiffness (young 16,446N/m vs. postmenopausal 23,229N/m, P<0.001), and muscle-tendon unit stiffness normalized by mass (young 286.3N/m vs. postmenopausal 325.1N/m, P<0.05). The postmenopausal study group shows significant lower values in the damping ratio (young 0.190 vs. postmenopausal 0.150, P<0.01) than young women.
INTERPRETATION: The postmenopausal subjects may not be able to take advantage of resonance as the young subjects, or, the relationship between these frequencies is adjusted according to the musculoskeletal characteristics of each group. The decrease in damping properties and the increase in muscle-tendon unit stiffness suggest that postmenopausal women might be at a greater risk of injury.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21277053     DOI: 10.1016/j.clinbiomech.2010.12.011

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  4 in total

1.  Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy.

Authors:  Franziska C Wagner; Sven Reese; Kerstin Gerlach; Peter Böttcher; Christoph K W Mülling
Journal:  BMC Vet Res       Date:  2021-06-25       Impact factor: 2.741

2.  Transcriptome analysis of ageing in uninjured human Achilles tendon.

Authors:  Mandy Jayne Peffers; Yongxiang Fang; Kathleen Cheung; Tim Koh Jia Wei; Peter David Clegg; Helen Lucy Birch
Journal:  Arthritis Res Ther       Date:  2015-02-18       Impact factor: 5.156

3.  Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons.

Authors:  Chavaunne T Thorpe; Graham P Riley; Helen L Birch; Peter D Clegg; Hazel R C Screen
Journal:  Acta Biomater       Date:  2017-03-16       Impact factor: 8.947

4.  Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading.

Authors:  Chavaunne T Thorpe; Graham P Riley; Helen L Birch; Peter D Clegg; Hazel R C Screen
Journal:  J R Soc Interface       Date:  2014-01-08       Impact factor: 4.118

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.