Literature DB >> 21271493

Reproducibility of muscle oxygen saturation.

C Thiel1, L Vogt, H Himmelreich, M Hübscher, W Banzer.   

Abstract

The present study evaluated the reproducibility of tissue oxygenation in relation to oxygen consumption (VO2) across cycle exercise intensities in a test-retest design. 12 subjects (25.7±2.1 years; 24.7±1.9 kg · m(-2)) twice performed an incremental bicycle exercise protocol, while tissue oxygen saturation (StO2) in the vastus lateralis muscle was monitored by a commercially available NIRS unit and VO2 determined by an open-circuit indirect calorimetric system. Coefficients of variation across rest, workloads corresponding to 25, 50 and 75% of individual maximum capacity, and maximum load were 5.8, 4.6, 6.1, 8.0, 11.0% (StO2) and 7.6, 6.0, 3.7, 3.4, 3.1% (VO2), respectively. 95 % CI of relative test-retest differences ranged from -5.6 to +5.4% at 25% load to -17.2 to +7.5% at maximum load for StO2 and from -7.3 to +7.7% at rest to -3.3 to +3.2% at maximum load for VO2. With advancing exercise intensity, within-subject variability of StO2 was augmented, whereas VO2 variability slightly attenuated. NIRS measurements at higher workloads need to be interpreted with caution. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21271493     DOI: 10.1055/s-0030-1269922

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  6 in total

1.  A low-cost, wireless near-infrared spectroscopy device detects the presence of lower extremity atherosclerosis as measured by computed tomographic angiography and characterizes walking impairment in peripheral artery disease.

Authors:  Matthew A Fuglestad; Hernan Hernandez; Yue Gao; Henamari Ybay; Molly N Schieber; Katyarina E Brunette; Sara A Myers; George P Casale; Iraklis I Pipinos
Journal:  J Vasc Surg       Date:  2019-08-21       Impact factor: 4.268

2.  Estimating the Lactate Threshold Using Wireless Near-Infrared Spectroscopy and Threshold Detection Analyses.

Authors:  Trent E Cayot; Shara G Robinson; Lindsay E Davis; Paul A Bender; John R Thistlethwaite; Craig E Broeder; Jakob D Lauver
Journal:  Int J Exerc Sci       Date:  2021-04-01

3.  Effects of inspiratory muscle warm-up on locomotor muscle oxygenation in elite speed skaters during 3000 m time trials.

Authors:  Philippe Richard; François Billaut
Journal:  Eur J Appl Physiol       Date:  2018-10-22       Impact factor: 3.078

4.  Oxygenation Threshold Derived from Near-Infrared Spectroscopy: Reliability and Its Relationship with the First Ventilatory Threshold.

Authors:  Stephan van der Zwaard; Richard T Jaspers; Ilse J Blokland; Chantal Achterberg; Jurrian M Visser; Anne R den Uil; Mathijs J Hofmijster; Koen Levels; Dionne A Noordhof; Arnold de Haan; Jos J de Koning; Willem J van der Laarse; Cornelis J de Ruiter
Journal:  PLoS One       Date:  2016-09-15       Impact factor: 3.240

5.  Test-retest reliability of skeletal muscle oxygenation measurement using near-infrared spectroscopy during exercise in patients with sport-related iliac artery flow limitation.

Authors:  Martijn van Hooff; Eduard J Meijer; Marc R M Scheltinga; Hans H C M Savelberg; Goof Schep
Journal:  Clin Physiol Funct Imaging       Date:  2022-01-25       Impact factor: 2.121

6.  Determination of the Respiratory Compensation Point by Detecting Changes in Intercostal Muscles Oxygenation by Using Near-Infrared Spectroscopy.

Authors:  Felipe Contreras-Briceño; Maximiliano Espinosa-Ramirez; Vicente Keim-Bagnara; Matías Carreño-Román; Rafael Rodríguez-Villagra; Fernanda Villegas-Belmar; Ginés Viscor; Luigi Gabrielli; Marcelo E Andía; Oscar F Araneda; Daniel E Hurtado
Journal:  Life (Basel)       Date:  2022-03-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.