Literature DB >> 21270353

Non-hardware posterior cruciate ligament reconstruction using knot/press-fit technique with periosteum-enveloped hamstrings tendon autograft.

Tai-Yuan Chuang1, Wei-Pin Ho, Chih-Hwa Chen, Ming-Hsin Shieh, Jiann-Jong Liau, Chang-Hung Huang.   

Abstract

BACKGROUND: Several posterior cruciate ligament reconstruction procedures have been proposed to manage ruptures.
PURPOSE: This study was intended to present the clinical results of non-hardware reconstruction of posterior cruciate ligament using a knot/press-fit technique with periosteum-enveloped autogenous hamstring tendons. STUDY
DESIGN: Case series; Level of evidence, 4.
METHODS: This arthroscopically assisted technique was used in 33 patients with posterior cruciate ligament ruptures. In this non-hardware technique, semitendinosus and gracilis tendons were prepared as 2 loops with knots. Each loop was enveloped in periosteum. After passing a bottleneck femoral tunnel, the grafts were fixed with a press-fit method (knotted grafts lodging in the bottleneck of the femoral tunnel). Simultaneously, the intra-articular opening of the tibial tunnel was filled with the periosteum-enveloped portion of the graft. A tie with Mersilene tape over a bone bridge for each tendon loop was used for tibial fixation.
RESULTS: The average follow-up was 35 months (range, 24-60 months). Clinical assessments included Tegner score, Lysholm knee score, International Knee Documentation Committee scores, thigh muscle assessment, and radiographic evaluation. The stress radiography results for posterior displacement changed from 13.7 ± 2.1 mm preoperatively to 4.8 ± 1.1 mm postoperatively. Average preinjury Tegner score was 5.9 (range, 3-9), decreasing to 2.9 (range, 2-5) preoperatively and increasing to 5.2 (range, 2-9) postoperatively. The Lysholm score increased from 58.5 ± 5.2 to 94.2 ± 4.1 (P < .01). Finally, 26 patients (89.7%) were assessed as nearly normal by International Knee Documentation Committee guidelines.
CONCLUSION: The study revealed satisfactory clinical subjective and objective results at a minimum of 2 years' follow-up. Without using hardware, this alternative technique has the advantage of no need for removal of hardware and potentially easier magnetic resonance imaging interpretation and revision surgery.

Entities:  

Mesh:

Year:  2011        PMID: 21270353     DOI: 10.1177/0363546510391178

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  2 in total

1.  [Effectiveness analysis of arthroscopic reconstruction of posterior cruciate ligament with embedded "tibial tendon bolt" fixation].

Authors:  Zhengping Sun; Chunyu Zhang; Yongyun Lian; Daifeng Lu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-04-15

2.  REHABILITATION FOLLOWING ISOLATED POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: A LITERATURE REVIEW OF PUBLISHED PROTOCOLS.

Authors:  Matthew Senese; Elliot Greenberg; J Todd Lawrence; Theodore Ganley
Journal:  Int J Sports Phys Ther       Date:  2018-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.