BACKGROUND: Adequate compliance with the existing guidelines for cleaning and disinfection of gastrointestinal endoscopes and accessories is necessary to obtain high-level disinfection and prevent pathogen transmission. AIM: To investigate cleaning and disinfection practice in China.
METHODS: A questionnaire with 21 questions concerning gastrointestinal endoscopy reprocessing was sent by e-mail to 189 endoscopy units in China.
RESULTS: One hundred and twenty-two (80.39%) of the 189 units responded. Compared with the low-workload units (<5000 procedures/year), the high-workload units (≥5000 procedures/year) had a significantly higher number of gastrointestinal endoscopes (25.8 ± 3.6 vs. 4.7 ± 1.8, p < 0.01) and the higher possessing rate of automated endoscope reprocessors (43.9% vs. 3.1%, p<0.01). Glutaraldehyde was the most commonly employed disinfectant (88.5%) in all the units. In 23/122 (18.8%) units, the exposure time to glutaraldehyde was <45 min in the case of infectious disease patients. Eighty-six of 122 (70.5%) units reused disposable materials, of which 21/86 (24.4%) reused disposable forceps and disposable polypectomy hooks, and 2/86 (1.6%) reused disposable injection needles intermittently.
CONCLUSION: Although gastrointestinal endoscopy has developed rapidly in China in the past decade, there is still room for improvement in the practice of endoscopy reprocessing, especially in middle-sized and small cities.
Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21269894     DOI: 10.1016/j.dld.2010.12.010

Source DB:  PubMed          Journal:  Dig Liver Dis        ISSN: 1590-8658            Impact factor:   4.088


  8 in total

1.  Current application situation of gastrointestinal endoscopy in China.

Authors:  Xiu-Li Zhang; Zhong-Sheng Lu; Ping Tang; Jin-Yan Kong; Yun-Sheng Yang
Journal:  World J Gastroenterol       Date:  2013-05-21       Impact factor: 5.742

Review 2.  Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?

Authors:  Günter Kampf; Patricia M Fliss; Heike Martiny
Journal:  World J Gastrointest Endosc       Date:  2014-09-16

3.  A pilot study on using chlorine dioxide gas for disinfection of gastrointestinal endoscopes.

Authors:  Ying Yi; Li-Mei Hao; Shu-Ren Ma; Jin-Hui Wu; Tao Wang; Song Lin; Zong-Xing Zhang; Jian-Cheng Qi
Journal:  J Zhejiang Univ Sci B       Date:  2016-07       Impact factor: 3.066

4.  Survey of endoscope reprocessing in Korea.

Authors:  Jeong Bae Park; Jae Nam Yang; Yun Jeong Lim; Ja Seol Koo; Jae Young Jang; Sang Hoon Park; Su Jin Hong; Sang-Woo Kim; Hoon Jai Chun
Journal:  Clin Endosc       Date:  2015-01-31

5.  Current status of endoscope reprocessing in Korea.

Authors:  Young-Seok Cho
Journal:  Clin Endosc       Date:  2015-01-31

6.  Recent update of gastrointestinal endoscope reprocessing.

Authors:  Kyong Hee Hong; Yun Jeong Lim
Journal:  Clin Endosc       Date:  2013-05-31

7.  Molecular epidemiologic characterization of a clustering HCV infection caused by inappropriate medical care in Heyuan City of Guangdong, China.

Authors:  Yi-Qun Kuang; Jin Yan; Yan Li; Xuhe Huang; Ye Wang; Guolong Yu; Xinge Yan; Ping Lin; Bing Qin; Peng Lin
Journal:  PLoS One       Date:  2013-12-03       Impact factor: 3.240

8.  National Endoscopy Quality Improvement Program Remains Suboptimal in Korea.

Authors:  Jae Myung Cha; Jeong Seop Moon; Il-Kwun Chung; Jin-Oh Kim; Jong Pil Im; Yu Kyung Cho; Hyun Gun Kim; Sang Kil Lee; Hang Lak Lee; Jae Young Jang; Eun Sun Kim; Yunho Jung; Chang Mo Moon; Yeol Kim; Bo Young Park
Journal:  Gut Liver       Date:  2016-09-15       Impact factor: 4.519

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.