BACKGROUND: Adequate compliance with the existing guidelines for cleaning and disinfection of gastrointestinal endoscopes and accessories is necessary to obtain high-level disinfection and prevent pathogen transmission. AIM: To investigate cleaning and disinfection practice in China. METHODS: A questionnaire with 21 questions concerning gastrointestinal endoscopy reprocessing was sent by e-mail to 189 endoscopy units in China. RESULTS: One hundred and twenty-two (80.39%) of the 189 units responded. Compared with the low-workload units (<5000 procedures/year), the high-workload units (≥5000 procedures/year) had a significantly higher number of gastrointestinal endoscopes (25.8 ± 3.6 vs. 4.7 ± 1.8, p < 0.01) and the higher possessing rate of automated endoscope reprocessors (43.9% vs. 3.1%, p<0.01). Glutaraldehyde was the most commonly employed disinfectant (88.5%) in all the units. In 23/122 (18.8%) units, the exposure time to glutaraldehyde was <45 min in the case of infectious disease patients. Eighty-six of 122 (70.5%) units reused disposable materials, of which 21/86 (24.4%) reused disposable forceps and disposable polypectomy hooks, and 2/86 (1.6%) reused disposable injection needles intermittently. CONCLUSION: Although gastrointestinal endoscopy has developed rapidly in China in the past decade, there is still room for improvement in the practice of endoscopy reprocessing, especially in middle-sized and small cities.
BACKGROUND: Adequate compliance with the existing guidelines for cleaning and disinfection of gastrointestinal endoscopes and accessories is necessary to obtain high-level disinfection and prevent pathogen transmission. AIM: To investigate cleaning and disinfection practice in China. METHODS: A questionnaire with 21 questions concerning gastrointestinal endoscopy reprocessing was sent by e-mail to 189 endoscopy units in China. RESULTS: One hundred and twenty-two (80.39%) of the 189 units responded. Compared with the low-workload units (<5000 procedures/year), the high-workload units (≥5000 procedures/year) had a significantly higher number of gastrointestinal endoscopes (25.8 ± 3.6 vs. 4.7 ± 1.8, p < 0.01) and the higher possessing rate of automated endoscope reprocessors (43.9% vs. 3.1%, p<0.01). Glutaraldehyde was the most commonly employed disinfectant (88.5%) in all the units. In 23/122 (18.8%) units, the exposure time to glutaraldehyde was <45 min in the case of infectious diseasepatients. Eighty-six of 122 (70.5%) units reused disposable materials, of which 21/86 (24.4%) reused disposable forceps and disposable polypectomy hooks, and 2/86 (1.6%) reused disposable injection needles intermittently. CONCLUSION: Although gastrointestinal endoscopy has developed rapidly in China in the past decade, there is still room for improvement in the practice of endoscopy reprocessing, especially in middle-sized and small cities.
Authors: Jeong Bae Park; Jae Nam Yang; Yun Jeong Lim; Ja Seol Koo; Jae Young Jang; Sang Hoon Park; Su Jin Hong; Sang-Woo Kim; Hoon Jai Chun Journal: Clin Endosc Date: 2015-01-31
Authors: Jae Myung Cha; Jeong Seop Moon; Il-Kwun Chung; Jin-Oh Kim; Jong Pil Im; Yu Kyung Cho; Hyun Gun Kim; Sang Kil Lee; Hang Lak Lee; Jae Young Jang; Eun Sun Kim; Yunho Jung; Chang Mo Moon; Yeol Kim; Bo Young Park Journal: Gut Liver Date: 2016-09-15 Impact factor: 4.519