Detection of tympanic membrane movement using film patch with integrated strain gauge, assessed by optical coherence tomography: experimental study.

T Just1, T Zehlicke, O Specht, W Sass, C Punke, W Schmidt, E Lankenau, D Behrend, H W Pau.   

Abstract

OBJECTIVE: We report an ex vivo and in vivo experimental study of a device designed to measure tympanic membrane movement under normal and pathological conditions, assessed using optical coherence tomography.
MATERIALS AND METHODS: We designed two types of flexible, round film patch with integrated strain gauge, to be attached to the tympanic membrane in order to measure tympanic membrane movement. Tympanic membrane attachment was assessed using optical coherence tomography. The devices were tested experimentally using an ex vivo model with varying middle-ear pressure.
RESULTS: Optical coherence tomography reliably assessed attachment of the film patch to the tympanic membrane, before and after middle-ear pressure changes. Strain gauge voltage changes were directly proportional to middle-ear pressure recordings, for low pressure changes. Tympanic membrane perforations smaller than 2 mm could be sealed off with the film patch.
CONCLUSION: Attachment of the film patch with integrated strain gauge to the tympanic membrane was not ideal. Nevertheless, the strain gauge was able to precisely detect small pressure changes within the middle ear, in this experimental model.

Mesh:

Substances:

Year:  2011        PMID: 21269559     DOI: 10.1017/S0022215110002859

Source DB:  PubMed          Journal:  J Laryngol Otol        ISSN: 0022-2151            Impact factor:   1.469


  5 in total

1.  Microanatomy of the tympanic membrane in chronic myringitis obtained with optical coherence tomography.

Authors:  Ellen Guder; Eva Lankenau; F Fleischhauer; H Schulz-Hildebrandt; G Hüttmann; H W Pau; Tino Just
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-11-11       Impact factor: 2.503

2.  [Assessment of chronic obstructive eustachian tube dysfunction : Evaluation of the German version of the Eustachian Tube Dysfunction Questionnaire].

Authors:  S Schröder; M Lehmann; H Sudhoff; J Ebmeyer
Journal:  HNO       Date:  2014-03       Impact factor: 1.284

3.  Endoscopic optical coherence tomography with wide field-of-view for the morphological and functional assessment of the human tympanic membrane.

Authors:  Lars Kirsten; Martin Schindler; Joseph Morgenstern; Mikael Timo Erkkilä; Jonas Golde; Julia Walther; Pascal Rottmann; Max Kemper; Matthias Bornitz; Marcus Neudert; Thomas Zahnert; Edmund Koch
Journal:  J Biomed Opt       Date:  2018-12       Impact factor: 3.170

4.  Investigations on the potential of optical coherence tomography as an imaging tool for eustachian tube.

Authors:  Xiao-Mei Sun; Jia-Qi Luo; Zhi-Wen Xiao; Qing-Yu Gu; Lin-Chan Lan; Hui-Qing Zhang; Guan-Ping Zhang
Journal:  Sci Rep       Date:  2021-04-13       Impact factor: 4.379

5.  [Evaluation of standardized questionnaires for diagnosis and differentiation of obstructive and patulous Eustachian tube dysfunction].

Authors:  J Lönnecker; N M Weiss; A Heinrichs; R Mlynski; S Rettschlag
Journal:  HNO       Date:  2021-03       Impact factor: 1.284

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.