Literature DB >> 21266557

Sonographically guided tendon sheath injections are more accurate than blind injections: implications for trigger finger treatment.

Dae-Hee Lee1, Seung-Beom Han, Jong-Woong Park, Soon-Hyuck Lee, Kwan-Woo Kim, Woong-Kyo Jeong.   

Abstract

OBJECTIVES: Trigger finger is frequently treated with tendon sheath injections. This cadaveric study evaluated the accuracy and safety of blind and sonographically guided tendon sheath injections. To our knowledge, a study that precisely mapped the locations of material injected into the tendon sheath has not been reported previously.
METHODS: A total of 40 fingers (excluding thumbs) of 5 fresh cadavers were used. Methylene blue dye was injected into the flexor tendon sheath using either a blind or sonographically guided injection technique (20 fingers for each technique). The location of the dye was then determined via dissection.
RESULTS: Dye was observed only in the tendon sheath (ie, optimal outcome) in 70% of sonographically guided injections and 15% of blind injections (P = .001). Dye was observed in the tendon proper (ie, unsafe outcome) in 30% of blind injections and 0% of sonographically guided injections (P = .02).
CONCLUSIONS: We found that sonographically guided tendon sheath injections were more accurate and may be potentially safer than blind injections. These findings suggest that sonographically guided injections should be considered over blind injections when treating trigger finger.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21266557     DOI: 10.7863/jum.2011.30.2.197

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  7 in total

1.  High-resolution ultrasound in the diagnosis of trigger finger and evaluation of response to steroid injection.

Authors:  Yutaka Mifune; Atsuyuki Inui; Ryosuke Sakata; Yoshifumi Harada; Fumiaki Takase; Masahiro Kurosaka; Takeshi Kokubu
Journal:  Skeletal Radiol       Date:  2016-10-08       Impact factor: 2.199

2.  A Survey of the Use of Ultrasound by Upper Extremity Surgeons.

Authors:  William L Wang; Kevin Kruse; John R Fowler
Journal:  Hand (N Y)       Date:  2016-04-27

3.  MRI in flexor tendon rupture after collagenase injection.

Authors:  Shruti Khurana; Vibhor Wadhwa; Avneesh Chhabra; Bardia Amirlak
Journal:  Skeletal Radiol       Date:  2016-11-25       Impact factor: 2.199

4.  The effects of hylan g-f 20 surface modification on gliding of extrasynovial canine tendon grafts in vitro.

Authors:  Michail N Kolodzinskyi; Chunfeng Zhao; Yu-Long Sun; Kai-Nan An; Andrew R Thoreson; Peter C Amadio; Steven L Moran
Journal:  J Hand Surg Am       Date:  2013-01-05       Impact factor: 2.230

Review 5.  Tendon injections - upper extremity.

Authors:  Flávio Duarte Silva; Fernando Zorzenoni; Lucas Nakasone Matos da Silva; Afranio Dos Reis Teixeira Neto; Marco Tulio Gonzalez; Alípio Gomes Ormond Filho; Júlio Brandão Guimarães
Journal:  Skeletal Radiol       Date:  2022-09-02       Impact factor: 2.128

6.  Stenosing tenosynovitis.

Authors:  V Vuillemin; H Guerini; H Bard; G Morvan
Journal:  J Ultrasound       Date:  2012-03-09

7.  Trigger Finger? Just Shoot!

Authors:  Stephen P Merry; Jason S O'Grady; Christopher L Boswell
Journal:  J Prim Care Community Health       Date:  2020 Jan-Dec