We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincaré sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21263175     DOI: 10.1088/0031-9155/56/4/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Conical scan polarization-sensitive optical coherence tomography.

Authors:  Zenghai Lu; Deepa Kasaragod; Stephen J Matcher
Journal:  Biomed Opt Express       Date:  2014-02-18       Impact factor: 3.732

2.  Structure tensor analysis of serial optical coherence scanner images for mapping fiber orientations and tractography in the brain.

Authors:  Hui Wang; Christophe Lenglet; Taner Akkin
Journal:  J Biomed Opt       Date:  2015-03       Impact factor: 3.170

Review 3.  Polarization sensitive optical coherence tomography - a review [Invited].

Authors:  Johannes F de Boer; Christoph K Hitzenberger; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

4.  Serial optical coherence scanner for large-scale brain imaging at microscopic resolution.

Authors:  Hui Wang; Junfeng Zhu; Taner Akkin
Journal:  Neuroimage       Date:  2013-10-04       Impact factor: 6.556

Review 5.  Optical phantoms for biomedical polarimetry: a review.

Authors:  Joseph Chue-Sang; Mariacarla Gonzalez; Angie Pierre; Megan Laughrey; Ilyas Saytashev; Tatiana Novikova; Jessica C Ramella-Roman
Journal:  J Biomed Opt       Date:  2019-03       Impact factor: 3.170

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.