Literature DB >> 21259437

Low thrombogenicity coating of nonwoven PET fiber structures for vascular grafts.

Sashka Dimitrievska1, Marion Maire, Gerardo A Diaz-Quijada, Lucie Robitaille, Abdellah Ajji, L'hocine Yahia, Maria Moreno, Yahye Merhi, Martin N Bureau.   

Abstract

Vascular PET grafts (Dacron) have shown good performance in large vessels (≥ 6 mm) applications. To address the urgent unmet need for small-diameter (2-6 mm) vascular grafts, proprietary high-compliance nonwoven PET fiber structures were modified with various PEG concentrations using PVA as a cross-linking agent, to fabricate non-thrombogenic mechanically compliant vascular grafts. The blood compatibility assays measured through platelet adhesion (SEM and mepacrine dye) and platelet activation (morphological changes, P-selectin secretion, and TXB2 production) demonstrate that functionalization using a 10% PEG solution was sufficient to significantly reduce platelet adhesion/activation close to optimal literature-reported levels observed on carbon-coated ePTFE.
Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21259437     DOI: 10.1002/mabi.201000390

Source DB:  PubMed          Journal:  Macromol Biosci        ISSN: 1616-5187            Impact factor:   4.979


  5 in total

Review 1.  Review of Polymeric Biomimetic Small-Diameter Vascular Grafts to Tackle Intimal Hyperplasia.

Authors:  Rumbidzai Zizhou; Xin Wang; Shadi Houshyar
Journal:  ACS Omega       Date:  2022-06-21

2.  Vascular grafts collagen coating resorption and healing process in humans.

Authors:  Elise Helfer; Salomé Kuntz; Delphine Dion; Frédéric Heim; Yannick Georg; Fabien Thaveau; Anne Lejay; Nabil Chakfé
Journal:  JVS Vasc Sci       Date:  2022-03-25

3.  Fabrication and surface modification of poly lactic acid (PLA) scaffolds with epidermal growth factor for neural tissue engineering.

Authors:  Tanit Haddad; Samantha Noel; Benoît Liberelle; Rouwayda El Ayoubi; Abdellah Ajji; Gregory De Crescenzo
Journal:  Biomatter       Date:  2016-10-14

4.  Synthesis and evaluation of poly(hexamethylene-urethane) and PEG-poly(hexamethylene-urethane) and their cholesteryl oleyl carbonate composites for human blood biocompatibility.

Authors:  Mei Fen Shih; Min Da Shau; Cheng Chih Hsieh; Jong Yuh Cherng
Journal:  Molecules       Date:  2011-09-28       Impact factor: 4.411

5.  A versatile star PEG grafting method for the generation of nonfouling and nonthrombogenic surfaces.

Authors:  Pradeep Kumar Thalla; Angel Contreras-García; Hicham Fadlallah; Jérémie Barrette; Gregory De Crescenzo; Yahye Merhi; Sophie Lerouge
Journal:  Biomed Res Int       Date:  2012-12-20       Impact factor: 3.411

  5 in total