Literature DB >> 21259393

Alternative CHCA-based matrices for the analysis of low molecular weight compounds by UV-MALDI-tandem mass spectrometry.

Tiffany Porta1, Chantal Grivet, Richard Knochenmuss, Emmanuel Varesio, Gérard Hopfgartner.   

Abstract

Analysis of low molecular weight compounds (LMWC) in complex matrices by vacuum matrix-assisted laser desorption/ionization (MALDI) often suffers from matrix interferences, which can severely degrade limits of quantitation. It is, therefore, useful to have available a range of suitable matrices, which exhibit complementary regions of interference. Two newly synthesized α-cyanocinnamic acid derivatives are reported here; (E)-2-cyano-3-(naphthalen-2-yl)acrylic acid (NpCCA) and (2E)-3-(anthracen-9-yl)-2-cyanoprop-2enoic acid (AnCCA). Along with the commonly used α-cyano-4-hydroxycinnamic acid (CHCA), and the recently developed 4-chloro-α-cyanocinnamic acid (Cl-CCA) matrices, these constitute a chemically similar series of matrices covering a range of molecular weights, and with correspondingly differing ranges of spectral interference. Their performance was compared by measuring the signal-to-noise ratios (S/N) of 47 analytes, mostly pharmaceuticals, with the different matrices using the selected reaction monitoring (SRM) mode on a triple quadrupole instrument equipped with a vacuum MALDI source. AnCCA, NpCCA and Cl-CCA were found to offer better signal-to-noise ratios in SRM mode than CHCA, but Cl-CCA yielded the best results for 60% of the compounds tested. To better understand the relative performance of this matrix series, the proton affinities (PAs) were measured using the kinetic method. Their relative values were: AnCCA > CHCA > NpCCA > Cl-CCA. This ordering is consistent with the performance data. The synthesis of the new matrices is straightforward and they provide (1) tunability of matrix background interfering ions and (2) enhanced analyte response for certain classes of compounds.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21259393     DOI: 10.1002/jms.1875

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  5 in total

1.  High throughput enzyme inhibitor screening by functionalized magnetic carbonaceous microspheres and graphene oxide-based MALDI-TOF-MS.

Authors:  Yang Liu; Yan Li; Junyan Liu; Chunhui Deng; Xiangmin Zhang
Journal:  J Am Soc Mass Spectrom       Date:  2011-09-27       Impact factor: 3.109

2.  Vibrational analysis of α-cyanohydroxycinnamic acid.

Authors:  Elmer-Rico E Mojica; Jayson Vedad; Ruel Z B Desamero
Journal:  J Mol Struct       Date:  2015-08-15       Impact factor: 3.196

3.  The Development of Novel Nanodiamond Based MALDI Matrices for the Analysis of Small Organic Pharmaceuticals.

Authors:  Jackson M Chitanda; Haixia Zhang; Erica Pahl; Randy W Purves; Anas El-Aneed
Journal:  J Am Soc Mass Spectrom       Date:  2016-08-03       Impact factor: 3.109

4.  Synthesis and Investigation of Novel CHCA-Derived Matrices for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Analysis of Lipids.

Authors:  Antonio Monopoli; Giovanni Ventura; Andrea Aloia; Fulvio Ciriaco; Angelo Nacci; Tommaso R I Cataldi; Cosima D Calvano
Journal:  Molecules       Date:  2022-04-15       Impact factor: 4.927

5.  Visualizing the distributions and spatiotemporal changes of metabolites in Panax notoginseng by MALDI mass spectrometry imaging.

Authors:  Chenglong Sun; Shuangshuang Ma; Lili Li; Daijie Wang; Wei Liu; Feng Liu; Lanping Guo; Xiao Wang
Journal:  J Ginseng Res       Date:  2021-04-17       Impact factor: 6.060

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.