Literature DB >> 21258198

[Efficacy of a self-designed protective lead shield in reduction of radiation exposure dose during endoscopic retrograde cholangiopancreatography].

Yun Jung Kim1, Kwang Bum Cho, Eun Soo Kim, Kyung Sik Park, Byoung Kuk Jang, Woo Jin Chung, Jae Seok Hwang.   

Abstract

BACKGROUND/AIMS: The increasing use of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography (ERCP) calls for greater consideration of radiation exposure risk to endoscopists and assistants, and emphasizes the proper system of radiation protection. This study was designed to assess the effect of a newly developed, self-designed, protective lead shield.
METHODS: A curtain-shaped protective shield composed of seven movable lead plates was developed, each with the following dimensions: depth, 0.1 cm; width, 15 cm; length, 70 cm. The curtain-shaped protective shield was designed to be located between the patient and the endoscopist. Twenty-nine patients (11 men and 18 women) undergoing ERCP between January 2010 and March 2010 were selected for this study. The dose of radiation exposure was recorded with or without the protective lead shield at the level of the head, chest, and pelvis. The measurement was made at 50 cm and 150 cm from the radiation source.
RESULTS: The mean patient age was 64 years. The mean patient height and weight was 161.7+/-6.9 cm and 58.9+/-9.9 kg, respectively. The mean body mass index (BMI) was 22.5+/-3.0 kg/m2. Endoscopists received 1522.2+/-537.0 mR/hr without the protective lead shield. At the same distance, radiation exposure was significantly reduced to 68.8+/-88.0 mR/hr with the protective lead shield (p-value>0.0001). The radiation exposure to endoscopists and assistants was significantly reduced by the use of a protective lead shield (p value >0.0001). The amount of radiation exposure during ERCP was related to the patient's BMI (r=0.749, p=0.001).
CONCLUSIONS: This self-designed, protective lead shield is effective in protecting endoscopists and assistants from radiation exposure.

Entities:  

Mesh:

Year:  2011        PMID: 21258198     DOI: 10.4166/kjg.2011.57.1.28

Source DB:  PubMed          Journal:  Korean J Gastroenterol        ISSN: 1598-9992


  3 in total

1.  A double-blind, randomized, sham-controlled trial of the effect of a radiation-attenuating drape on radiation exposure to endoscopy staff during ERCP.

Authors:  Thiruvengadam Muniraj; Harry R Aslanian; Loren Laine; James Farrell; Maria M Ciarleglio; Yanhong Deng; Henry Ho; Priya A Jamidar
Journal:  Am J Gastroenterol       Date:  2015-03-31       Impact factor: 10.864

2.  A novel removable shield attached to C-arm units against scattered X-rays from a patient's side.

Authors:  Hiroshige Mori; Kichiro Koshida; Osamu Ishigamori; Kosuke Matsubara
Journal:  Eur Radiol       Date:  2014-05-02       Impact factor: 5.315

3.  Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study.

Authors:  Kwang Hyun Chung; Young Sook Park; Sang Bong Ahn; Byoung Kwan Son
Journal:  BMJ Open       Date:  2019-03-20       Impact factor: 2.692

  3 in total