Literature DB >> 21256895

Development of a combined immunomagnetic separation and quantitative reverse transcription-PCR assay for sensitive detection of infectious rotavirus in water samples.

Wan Yang1, April Z Gu, Si-yu Zeng, Dan Li, Miao He, Han-chang Shi.   

Abstract

A quantitative and rapid detection method for rotavirus in water samples was developed using immunomagnetic separation combined with quantitative reverse transcription-polymerase chain reaction (IMS-RT-qPCR). Magnetic beads coated with antibodies against representative group A rotavirus were used to capture and purify intact rotavirus particles in both artificial and real environmental water sample matrix. Compared to extracting RNA using commercial kits and RT-qPCR assay, the developed IMS-RT-qPCR method increased the detection sensitivity by about one order of magnitude when applied in clean water, with a detection limit of 3.16 50% tissue culture infectious dose (TCID(50))/mL within 5h. This method was compatible with various commonly used virus eluants, including beef extract (BE), beef extract with 0.05M glycine (BEG) and urea arginine phosphate buffer (UAPB). The recovery efficiencies from various eluants using IMS-RT-qPCR are higher than that using direct RT-qPCR method, demonstrating the effectiveness of the IMS step for eliminating inhibitors in the eluant matrix. This method was also successfully applied to purify and detect rotavirus particles seeded in 10(3)-fold concentrated wastewater influent samples. It seemed to reduce the interference from complex sample background and increase the qPCR product reliability comparing to RT-qPCR method without the IMS step. The results indicated that IMS-RT-qPCR is a rapid, sensitive and reliable tool for detecting rotaviruses in complex water environments.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21256895     DOI: 10.1016/j.mimet.2011.01.011

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  4 in total

1.  Development of low cost two-step reverse transcription-quantitative polymerase chain reaction assays for rotavirus detection in foul surface water drains.

Authors:  J W Chung; J W Foppen; P N L Lens
Journal:  Food Environ Virol       Date:  2013-04-11       Impact factor: 2.778

Review 2.  Detection and evaluation of rotavirus surveillance methods as viral indicator in the aquatic environments.

Authors:  Paymaneh Atabakhsh; Mohammad Kargar; Abbas Doosti
Journal:  Braz J Microbiol       Date:  2021-02-18       Impact factor: 2.476

Review 3.  Methods to detect infectious human enteric viruses in environmental water samples.

Authors:  Ibrahim Ahmed Hamza; Lars Jurzik; Klaus Überla; Michael Wilhelm
Journal:  Int J Hyg Environ Health       Date:  2011-09-15       Impact factor: 5.840

4.  Development of lectin-linked immunomagnetic separation for the detection of hepatitis a virus.

Authors:  Sang-Mu Ko; Joseph Kwon; Bipin Vaidya; Jong Soon Choi; Hee-Min Lee; Myung-Joo Oh; Hyeun-Jong Bae; Se-Young Cho; Kyung-Seo Oh; Duwoon Kim
Journal:  Viruses       Date:  2014-03-04       Impact factor: 5.048

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.