The effects of needleless connectors on catheter-related bloodstream infections.

Imad F Btaiche1, Debra S Kovacevich, Nabil Khalidi, Lorelei F Papke.   

Abstract

Needleless connectors, including the standard split septum and the luer-activated mechanical valve connectors, have been introduced into clinical practice to eliminate the risk of needlestick injuries by avoiding the use of needles when accessing the intravascular catheters. Negative and positive displacement mechanical valves have been associated with increased rates of catheter-related bloodstream infections as compared with split septum connectors. Based on available data, split septum connectors should be preferentially used instead of mechanical valves. Adequate disinfection by scrubbing the access port preferably with chlorhexidine is recommended to minimize the risk of catheter microbial contamination along with proper infection control practices. Large prospective randomized clinical trials are needed to evaluate further the possible causes and effects of different types of mechanical valve needleless connectors on bloodstream infections.
Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21256629     DOI: 10.1016/j.ajic.2010.07.011

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  7 in total

1.  Outbreak column 19: needleless connectors (NCs) tales from nine outbreaks.

Authors:  Evonne Curran
Journal:  J Infect Prev       Date:  2016-06-30

2.  Reducing the degree of colonisation of venous access catheters by continuous passive disinfection.

Authors:  Fernando Gutiérrez Nicolás; Gloria Julia Nazco Casariego; María Micaela Viña Romero; Jonathan González García; Ruth Ramos Diaz; Jose Antonio Perez Perez
Journal:  Eur J Hosp Pharm       Date:  2015-10-12

Review 3.  Disinfection of Needleless Connector Hubs: Clinical Evidence Systematic Review.

Authors:  Nancy L Moureau; Julie Flynn
Journal:  Nurs Res Pract       Date:  2015-05-14

4.  In vitro study on the disinfectability of two split-septum needle-free connection devices using different disinfection procedures.

Authors:  Steffen Engelhart; Martin Exner; Arne Simon
Journal:  GMS Hyg Infect Control       Date:  2015-12-09

5.  Patient safety in nursing care during medication administration.

Authors:  Júlian Katrin Albuquerque de Oliveira; Eliana Ofélia Llapa-Rodriguez; Iza Maria Fraga Lobo; Luciana de Santana Lôbo Silva; Simone de Godoy; Gilvan Gomes da Silva
Journal:  Rev Lat Am Enfermagem       Date:  2018-08-09

6.  The Impact of Open versus Closed Catheter Access System of Central Venous Catheter on Infection Prevention in Critically Ill Patients: A Comparative Evaluation.

Authors:  Davinder Kaur; Surinder Jaspal; Sukhminderjit Singh Bajwa
Journal:  Iran J Nurs Midwifery Res       Date:  2020-11-07

7.  The Efficacy, Safety, and Convenience of a New Device for Flushing Intravenous Catheters (Baro Flush™): A Prospective Study.

Authors:  Youn I Choi; Jae Hee Cho; Jun-Won Chung; Kyoung Oh Kim; Kwang An Kwon; Han Yong Chun; Dong Kyun Park; Yoon Jae Kim
Journal:  Medicina (Kaunas)       Date:  2020-08-05       Impact factor: 2.430

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.